CAUTION:
Do not move the device, as otherwise this might cause
the water to leak out and damage the fl oor, carpet or
device.
Never use the air-conditioner without protective fi lters.

Unpacking the appliance

Remove the appliance from the box and all the enclosed
accessories.
Do not through the packaging away, but keep it together with
the inner packing and the warranty documents for the whole
life of the warranty.
Place the appliance on smooth, level and stable work
surface.
Do not insert the appliance plug without installing the
necessary attachments.
Installation
Installing the Exhaust Air Hose
Place the connection ring (11) over the exhaust air hose
(10). Turn the connection ring at least fi ve times in a clockwi-
se direction until it is tight. Check that it cannot be pulled off.
Push the assembled exhaust air hose from right to left
over the hose connection (9) on the back. Guide it into the
holders until it locks in place. In order to release the hose
again, press in the right-hand retainer and push the hose to
the right out of the holder.
NOTE:
If the device is in „cooling" mode the end of the exhaust air
hose has to be led out of the air-conditioned room.
Mains Lead Take-up
Unwind the mains lead from the cable holder on the rear of the
device. After using the device, please wind up the lead again.

Initial Operation

Only connect the machine to a properly installed safety
socket, 230 V/50 Hz.
Make sure that the degree of protection of the socket to
which the device is connected is of at least 10 ampere!
Place the device on any heat-resistant fl at surface. Ensure
that air can enter and leave unhindered.
The distance from the air inlet grille (5/7) to the nearest wall
should be at least 20 cm. The distance from the air outlet
grille (2) to the nearest wall should be more than 1m.
Switching on/off
1. As soon as you have inserted the plug the mains control
lamp (J) lights up in red and indicates that the device is
connected to the mains.
2. Press the „ " button (J) (13 on the remote control) to switch
the device on - the control lamp lights up in green. An
acoustic signal is heard and the digital display (E) shows
22 °C.
Please wait until the device has begun operation.
The device switches to the highest speed and the „cooling"
18
05-CL 3134 18
mode (the „
" control lamp lights up in red and the
" control lamp in green). The air outlet (2) opens.
After a few seconds the device switches on automatically.
Mode of Operation
Press the „ " button (H/14) to switch the mode of operation bet-
ween "cooling" (green), „dehumidifi er" (orange) and "ventilator"
(no lamp).
NOTE:
Changing the Mode of Operation
When the mode of operation is changed the compressor
remains switched off for approximately 6 minutes until the
pressure in the refrigeration circuit has eased.
Then the compressor switches on again automatically.
Cooling
If you would like to change the room temperature using the
„cooling" mode of operation, press the „ " or „ " button
(D/F). The digital display (E) shows the temperature (min.
18°C – max. 32°C). The temperature increases or reduces
by 1°C with each press of the button.
By repeatedly pressing the „ " button (18) on the remote
control you can switch from 18, 19, 20.....32; from there it
returns to 18, 19 etc.
The device cools the room down to the set temperature,
which it then maintains. If the set temperature is above the
current room temperature, the device switches the cooling
off and only the ventilator continues running.
NOTE:
The rate at which the desired temperature is reached depends
on the temperature of the room and the outside temperature.
Ventilator Speed
In the „cooling" and „ventilator" modes it is possible to set 3 dif-
ferent levels for the speed of the ventilator. The speed changes
with each press of the „
Red
– for a high speed
Green – for a medium speed
Orange – for a slow speed

Timer Functions

Switch-off Timer
1. Turn the device on with the „ " button (J/13).
2. Briefl y press the „ " button (B/17) to change over to timer
adjustment. The digital display on the control panel fl ashes
and shows 00. The „ " control lamp lights up in green.
3. Press the button repeatedly to programme the timer. The
length of time is increased with every press of the button by
1 hour (00, 01, 02.....24, then from the beginning again).
4. After the set time has expired the device switches off.
Switch-on Timer
Before you use the switch-on timer turn the device on and set
the mode of operation, the ventilator speed and temperature.
" button (G/15):