The device displays the selected settings on the control panel
(Fig. 3).
1. Turn the device off with the „ " button (J/13).
2. Briefl y press the „ " button (B/17) to change to the time
setting mode. The digital display on the control panel fl ashes
and shows 00. The „ " control lamp lights up in green.
3. In order to programme the timer, press the „ " button (B/17)
repeatedly. The length of time increases by 1 hour with
every press of the button (00, 01, 02.....24, then from the
beginning again).
4. After the set time has expired, the device switches on.
If you would like to switch off the timer before the time has
expired, press the „ " button (B/17) repeatedly until the digital
display shows 00. The timer is now switched off.

Sleep Mode

Please wait until the device has begun operation as described
under the section „Switching on/off", or if the device is already
working, please proceed as follows:
Press the „ " button (C) to switch on the sleep mode.
In sleep mode the ventilation speed is preset to low (orange
lamp).
The speed can be set or changed by pressing the „
button (G/15).
In sleep mode the previously selected temperature increa-
ses by 1°C after 1 hour and by a further 1°C after 2 hours.
In order to switch sleep mode off again, press the „ " button
once more.
Dehumidifying
When the device is operated in the „dehumidify" mode you
should allow the exhaust air to fl ow back into the room.
During dehumidifi cation only the low ventilator speed is possible
" control lamp lights up in orange). In this mode of
(„
operation it may be necessary to empty the condensation
container more frequently (see section on „Emptying the Water
Container").
Air Outlet
Press the „ " button (J/13) to open the air outlet.
Press the „ " on (A/16) and the air outlet moves conti-
nuously up and down.
The movement is stopped by repeatedly pressing the „ "
button and the air slit remains in this position. The direction
of the airfl ow is then constant.
Once the „ " button has been pressed the air outlet closes.
Emptying the Water Container
Under conditions of high humidity it may be necessary to empty
the internal condensation container. When the water container is
full, an acoustic signal is heard 15 times. The device switches off
automatically and the „
order to empty the water container, please proceed as follows:
05-CL 3134 19
" (K) control lamp lights up in red. In
Turn the device off („ " control lamp lights up in red) and
remove the plug from the socket.
CAUTION:
Do not move the device, as otherwise this might
cause the water to leak out and damage the fl oor,
carpet or device.
Place the collecting pan supplied on the fl oor under the
outlet (12) of the device (see Fig. 5).
Remove the rubber bung from the outfl ow and allow the
water to drain out (Fig. 6).
"
CAUTION:
Do not remove from the device during the emptying
process! As the internal water container can hold up to
3 litres it is necessary to close the outfl ow from time to
time and empty the collecting pan. Repeat the process if
necessary until no further water fl ows out of the device.
Close the outfl ow again with the rubber bungs. Insert the
plug into the socket and switch the device on. The red water
full display is switched off.
NOTE: Empty the water container regularly.
Air Filters
The air conditioner is equipped with two protective fi lters in order
to clean the air in the room.
NOTE:
When the device has been running for more than 100 hours
the digital display (E) fl ashes to remind you that the fi lter
should be cleaned. Press the „ " and „ " buttons simultane-
ously to stop the digital display from fl ashing.
Fig. 5
Fig. 6
19