INSTALLATION INSTRUCTIONS

The installation comes under the exclusive responsibility of specialists.
The installer is held to respect the legislation and the standards enforce in his home country.
How to stick the gasket:
The gasket supplied with the hob avoids all infiltration of liquids in the cabinet.
His installation has to be done carefully, in conformity of the following drawing.
Fitting - installing:
 The cut out sizes are:
Cut size
Ref.
Width
1767
980 mm
 Ensure that there is a distance of 50 mm between the hob and the wall or sides.
 The hobs are classified as "Y" class for heat protection. Ideally the hob should be installed
with plenty of space on either side. There may be a wall at the rear and tall units or a wall
at one side. On the other side, however, no unit or divider must stand higher than
the hob.
 The piece of furniture or the support in which the hob is to be fitted, as well as the edges of
furniture, the laminate coatings and the glue used to fix them, must be able to resist
temperatures of up to 100 °C.
 The mural rods of edge must be heat-resisting.
 Not to install the hob to the top of a not ventilated oven or a dishwasher.
 To guarantee under the bottom of the hob casing a space of 20 mm to ensure a good air
circulation of the electronic device.
 If a drawer is placed under the work, avoid to put into this drawer flammable objects
(for example: sprays) or not heat-resistant objects.
 Materials which are often used to make worktops
expand on contact with water. To protect the cut out
edge, apply a coat of varnish or special sealant.
Particular care must be given to applying the adhesive
joint supplied with the hob to prevent any leakage into
the supporting furniture. This gasket guaranties a
correct seal when used in conjunction with smooth
work top surfaces.
 The safety gap between the hob and the cooker hood
placed above must respect the indications of the hood
manufacturer. In case of absence of instructions
respect a distance minimum of 760 mm.
 The connection cord should be subjected, after
building, with no mechanical constraint, such for
example of the fact of the drawer.
Cut size flush mounting
Depth
Width
350 mm
1006 mm
Stick the gasket (2) two millimeters
from the external edge of the glass,
after removing the protection sheet (3).
Depth
Radius
406 mm
8 mm
1000 mm
>71mm
65
Glass size
Width
Depth
Thickness
400 mm
4 mm