Connection with the mains

Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.

OPERATION

After you connected the effect to the mains, the LED IP T1000 TCL starts running.
The LED display lights up and you can now choose the desired settings via the buttons MENU, UP, DOWN
and ENTER.
The device has two operating modes. It can be operated in stand-alone mode or in DMX-controlled mode via
any standard DMX controller.

Stand-alone Mode

In the stand-alone mode, the LED IP T1000 TCL can be used without DMX-controller. Disconnect the LED
IP T1000 TCL from the DMX-controller.