1.2 Installation

Fuels
The equipment can be used with fuels detailed in the followings. This way the "low-
smoke" and trouble-free operation can be secured. Use only dry wood with mois-
ture of maximum 20%.
Filling quantities
-Split billet: max. length: 35 cm
max. 2 billets per filling, appr. 2.1 kg
-Lignite briquette: max. 2.2 kg
Fuel
Warning up,
kindling
Wood
Brown-coal
Putting out of working
order
IT IS NOT ALLOWED to burn waste, fine chipping, bark, wood handled with
preventive chemicals, furthermore paper and cardboard. For kindling please
use wood scrapings or grill starter but never use liquid auxiliaries!
The first kindling
At the first fire set-up could be a little smoke, but is not dangerous, normal!
In this time, please ventilate the room carefully!
Warning! Upon the first kindling, smoke and unpleasant smell may be
generated. Always ensure the proper ventilation of the room (by opening
windows and doors), and heat the fireplace at maximum rated heating
performance. If with the first heating the maximum temperature is not
reached, the above-mentioned effects may as well arise later on.
Types of fuels
Hard wood
Soft wood
Brown-coal
Nominal heating
performance
Nominal heating
performance
Heating value
appr. KJ/kg
19.500
14.600
11.500
Setting of the primary air
regulator
IIII
II
III
I
Table 2