Herunterladen Inhalt Inhalt Diese Seite drucken

WolfVision VZ-C12 Montageanleitung Seite 5

Vorschau ausblenden Andere Handbücher für VZ-C12:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INSTALLATION POSITION
A difference between Ceiling- and "Desktop-"Visualizers is that the size of the smallest and largest image
the unit can pick up is not fixed. This depends on how high above the working surface the Visualizer is
mounted. It is very important to know which image sizes you would like to pick up with the Ceiling
Visualizer before installing the unit, in order to correctly calculate the respective mounting height.
Please refer to the calculation program on WolfVision's homepage (see page 5).
Distance to image center
The following table shows the distance which is
called "x" in the illustration on the right side:
in mm
in mm
Distance
Distance
Visualizer to
Visualizer-
working
front to
surface
image center
1,100
66
1,200
99
1,400
164
1,600
229
1,800
294
2,000
359
2,200
424
2,400
489
2,600
554
2,800
619
3,000
684
3,200
749
3,400
814
3,600
879
3,800
944
4,000
1,009
4,200
1,074
4,400
1,139
4,600
1,204
4,800
1,269
5,000
1,334
IMPORTANT:
The center of the image is offset 87.5 mm (3.5 ") to the
right, from the middle of the Visualizer housing !
in Inch
in Inch
Distance
Distance
Visualizer to
Visualizer-
working
front to
surface
image center
44
2.84
50
4.79
60
8.04
70
11.28
80
14.53
90
17.78
100
21.03
110
24.28
120
27.53
130
30.78
140
34.03
150
37.28
160
40.53
170
43.78
180
47.03
190
50.27
200
53.52
In extremely high rooms the smallest image the
unit can pick-up may not be small enough. In
such cases a standard ceiling mount or
projector-lift can be used to suspend the Ceiling
Visualizer further from the ceiling.
206 mm
8.11 inch
452 mm / 17.8 inch
Audience
4
ceiling
suspended ceiling
x
(if required)
x mm = distance * tan 18° - 291mm
x"
= distance * tan 18° - 11.45"
(tan 18° = 0.3249)
18°
y
87,5 mm / 344"

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Vz-c32

Inhaltsverzeichnis