Cluster Mounting WITH extra accessories
• Up to 16 TPiX.7 can be mounted as one device by use of the
TPiX.7 hanging bar. At this point it is possible to mount up to
16 TPiX.7 among themselves or up to 8 TPiX.7 among them­
selves and up to 2 TPiX.7 in parallel (see figure).
Only use the TPiX.7 hanging bar for the mounting on the
truss or any other suitable hanging point plus suitable hooks/
clamps approved by the BGV C1 for this kind of installation.
The panels will be locked in vertical line by the use of ¼ turn
locks.
Use the allen key supplied with the unit to lock the panels in
vertical line. Make sure to turn the ¼ turn locks safely as far
as they will go.
NOTE!
The connection elements mounted at the sides of TPiX.7 are
only used for alignment – means the connection of multiple
TPiX.7 together. These connection elements are NOT used for
static loads and cannot be used for mounting of TPiX.7 !
Make sure to safe the fixture by a safety chain which is speci-
fied at least with a load limit of 12 times of the fixtures weight.
Only safety chain with approved connective can be used. At-
tach the safety chain to its designated opening and attach it to
the truss system or a similar and safe attachment point. Assure
to close the fasteners as specified.