Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Cleaning And Maintenance - Omnitronic ASS-1023 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7

OPERATION

1
First turn down the MASTER control for the overall volume to the left stop position to avoid a possible
switching-on noise. Then switch on the PA monitor. The PWR indicator lights
2
Turn up the MASTER control so that the mixing ration of the signal sources can be adjusted in an
optimum way.
3
Adjust the desired volume ratio with the level controls MIC and LINE LEVEL of the microphone channel
and the line input. Only turn up the controls to such an extent that the sound reproduction will not be
distorted. The LIMIT indicator lights up when the signal level is too high so that the level limitation will
be activated. If this indicator lights up frequently, reduce the volume of the input signals accordingly.
4
Adjust the desired volume for the subwoofer with the control SUBWOOFER LEVEL.
5
Should a turn of phase occur during the signal transmission, the phase between subwoofer signal and
column speaker signal can be turned by 180° with the PHASE selector switch.
6
Adjust the definite level of the overall volume with the MASTER control.
7
When operating the PA system, please make sure that the loudspeakers always sound well. When
distortions can be heard, either the amplifier or the loudspeakers are overloaded. Overloads can quickly
lead to amplifier or speaker damage. In order to avoid damage, please reduce the volume immediately
when distortions can be heard. When speaker systems are destroyed by overload, the guarantee
becomes void. Always check the sound pressure level with a meter in order to keep to the threshold.
8
After operation, set the MASTER control to minimum, then switch off the PA system with the power
switch. The power indicator extinguishes.
..............................................................................................................................................................................
8

CLEANING AND MAINTENANCE

We recommend a frequent cleaning of the PA system. Please use a soft lint-free and moistened cloth. Never
use alcohol or solvents!
There are no serviceable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers. Should you need any spare parts, please use genuine parts. If
the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
If the stage PA system distorts, one of the loudspeakers may be defective. In this case the system should
not be operated any more in order to prevent further damage. Please contact your dealer. If clacking sounds
are heard from the system, screws may have loosened due to the continuous vibrations. The system should
be checked by a specialist.
Should you have further questions, please contact your dealer.
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
18