Failure: The ozone producer is not operational,
although the „O3" LED is lit.
Cause: The fuse in the switched socket outlet is
defective.
Remedy: An electrician has to open the switched
socket outlet to replace the 8 A fuse.
Failure: The ozone producers switches on and
off, although the mV reading is still much too
low.
Cause: TIMER in operation.
Remedy: Check whether the timer function is
useful, otherwise set the knob to „TIMER off".
Failure: The readings vary considerably.
Cause: Electrical potential in the water caused by
other devices.
Remedy: Connect the aquarium water to earth, i.e,
install a grounding probe; remove any foreign
devices, if and when applicable.
Cause: The ozone source is too close to the
electrode.
Remedy: Attach the electrode at another location
as far away from the ozone source as possible.
Disfonctionnements:
n'est pas en service malgré le fonctionnement
de la LED „ O3 ".
Raisons: Fusible défectueux dans la prise
commandée.
Solutions: La prise commandée doit être ouverte
par un professionnel en électricité afin de
remplacer et le fusible 8A.
Disfonctionnements:
s'allume et s'éteint successivement malgré une
mesure mV bien trop faible.
Raisons: TIMER en fonction.
Solutions: Veuillez vérifier l'utilité de cette fonction
dans votre utilisation, sinon positionnez sur
„ TIMER OFF ".
Disfonctionnements: La mesure est soumise à
de fortes variations.
Raisons: Potentiel électrique dans l'eau en raison
de la présence d'appareils annexes.
Solutions: L'eau de l'aquarium doit être reliée à la
terre, évent. retirer les appareillages annexes.
Raisons:
Source
l'électrode.
Solutions: L'électrode doit être déplacée, si
possible loin de la source d'ozone.
Le générateur d'ozone
Le générateur d'ozone
d'ozone
trop
proche
de
59