Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Mode (Alde Compact 3010); Heating Timer - Truma Vicon 2 Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für Vicon 2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating mode
(Alde Compact 3010)
If the Alde Compact 3010 heating system is installed in the
vehicle, a menu with the current settings is shown.
R
22° C
2 kW
ON
OFF
ON
Button to the "Timer" menu of the heating system.
If the timer is switched on, the button is green.
Room temperature
The current set room temperature is displayed and can be
changed.
R
22° C
2 kW
2 kW
ON
ON
OFF
OFF
ON
ON
In the summer when only warm water is required, set
the room temperature to a level that is lower than the
current room temperature to prevent the pump in the heating
system from starting.
Warm water
If more warm water is required, the water temperature can be
increased temporarily from 50 °C to 65 °C. The function is ac-
tivated by pressing the button "+" once. If more warm water
was selected, the pump in the heating system stops.
To reduce the amount of warm water, i.e. to reset the system
back to normal, pressure the button "–" once.
R
22° C
22° C
2 kW
2 kW
ON
ON
OFF
OFF
ON
ON
Warm water (60 °C) and heating
Warm water (65 °C) without heating (the pump in the
heating system is switched off)
Electro mode
If the vehicle is connected to 230 V ~ / 50 Hz, this is recog-
nized by the heating system which prefers the electro mode.
If necessary the gas burner is also activated.
R
22° C
22° C
2 kW
ON
ON
OFF
OFF
ON
ON
The electrical output is 1 kW, 2 kW or 3 kW depending on the
configuration. The higher the selected output, the faster the
heating process.
If the heating system is
switched on, the warm
water is always avail-
able (50 °C). The heating
system is operated electri-
cally or with liquid gas.
Decreases the room
temperature (min. 5 °C)
by 1 °C
Increases the room
temperature (max. 30 °C)
by 1 °C
Decreases the warm wa-
ter quantity
Increases the warm water
quantity
Decreases the electrical
output by 1 kW. To switch
off the electro mode,
keep pressing until "0" or
"OFF" appears.
Increases the electrical
output by 1 kW.
Gas mode
The gas mode of the heating system is switched on / off. The
heating output of the burner is regulated depending on the
heat needs. When the electro mode is operated at the same
time, the electro mode takes priority.
R
22° C
22° C
2 kW
2 kW
ON
OFF
ON

Heating timer

The set room temperature becomes active at a preset time.
The room temperature setting is kept until changed.
18 °C
ON
10
0 0
Time
18 °C
To set the room temperature, first press the tempera-
ture button. Enter the temperature using the buttons
"+" and "–".
Time
To set the start time, first press the hour or minute
button. Enter the start time (hours in 24 h mode)
using the buttons "+" and "–".
Activate the timer with this button.
The timer is activated and
The heating is activated
The timer sets the heating to the defined room temperature
at the start time.
The heating is deactivated
The timer switches on the heating to the defined room tem-
perature at the start time.
The gas mode is activat-
ed, the "ON" button turns
green.
The gas mode is switched
off, the "OFF" button
turns green.
17