Alarm code (PIN / Super PIN)

With this function, the PIN can be changed or the Super PIN
entered (PIN, Super PIN see documents provided by the vehi-
cle manufacturer).
PIN (4-digit)
enter / confirm current PIN,
enter / confirm new PIN and
enter / confirm new PIN again.
Super PIN (8-digit)
Enter / confirm SUPER PIN
Code
Code
22. 04. 10
22. 04. 10
Code
12 V
12 V
1...0
Buttons for entering the PIN / Super PIN
Emend entry
Cancel entry and return to previous menu
Confirm entry and return to previous menu

Acknowledge sound for "switch on / off"

When this function is activated, an acknowledgment sound is
issued when the display is touched and the button is shown
in green. The acknowledgment sound is switched on or off
when the button is pressed.
Code
Code
22. 04. 10
22. 04. 10
12 V
12 V

Brightness

Code
Code
22. 04. 10
22. 04. 10
12 V
12 V
Set the required brightness of the display.
Brightness in the "Active" mode
Brightness in the "Sleep" mode
1
2
3
Change alarm code?
Input your
4
5
6
current pin
7
8
9
9 5 8 6
0
C
OK
100
%
10
%
Other settings – Level 2
Depending on the vehicle model, the menu may have two lev-
els. It is possible to switch between the two levels by touching
the button.
Code
Code
22. 04. 10
22. 04. 10
12 V
12 V

Current limiter 230 V

This function is only available if a current limiter has been
installed.
Alde Compact 3010
The current limiter reduces or shuts down the electro
mode of the heating system when the set power strength
is exceeded.
This avoids the fuse being triggered if several consumers are
operated at the same time.
230 V Amp
Set the required current. Due to voltage variations and toler-
ances, different settings can be selected (for a 10 A fuse
e.g. 9 A, 10 A, 11 A). If the fuse triggers anyway, a lower value
must be set.
Increases the current (max. 17 A) by 1 A
Decreases the current (min. 5 A) by 1 A
Activation of the current limiter (button is green)
If more current consumers are connected, ensure that the
total power consumption does not overload the fuse to which
the vehicle is connected.

Stand-by

The Vicon System switches to stand-by if
All outputs (consumers) are inactive for a period of time set
by the vehicle manufacturer
or
Stand-by is activated e.g. via a button.
In the stand-by mode the heating switches off automati-
cally. If the system is awakened, the heating needs to be
switched on again.
230 V Amp
10
EIN
Ampere
19