Operating mode
(Truma Combi)
Operating mode
The current set room temperature is displayed and can be
changed.
20°C
Button to the "Timer" menu of the heating system.
If the timer is switched on, the button is green.
Possible options (depending on the heating device):
Switch on / off heating system. If the heating system
is switched on, the button is green.
Heating is switched on
Winter mode (heating + warm water)
Symbol activated
Water temperature 60 °C switched on
(Heating with controlled water temperature).
Symbol deactivated
Water temperature 60 °C switched off
(Heating without controlled water temperature).
Heating is switched off
Summer mode (warm water – without heating)
Water temperature 40 °C or
Water temperature 60 °C
Energy choice
In the case of heating system with an electro mode
(Combi 4 E / 6 E), an additional menu column is displayed
for the energy selection.
20°C
20°C
4 A
40° C
40° C
60°C
60°C
8A
Possible options (depending on the heating device):
Switch on / off gas mode
and / or
Electro mode half power or
Electro mode full power
16
Increases the room
temperature (max. 30 °C)
by 1 °C
Decreases the room
temperature (min. 5 °C)
by 1 °C
Heating / room temperature
This menu shows the status of the heating system.
The heating can be switched on or off. There is a but-
ton to the "Operating mode" menu for the heating
system.
R
20°C
1 kW
C
C
1
1
The LED shows the following statuses:
LED off
The heating is switched off
LED on
The heating is switched on
LED flashes and
Error
the warning / error
The heating
message
is blocked.
"Gas Failure" is
shown in the
display.
The heating
has
overheated
Fault in the
sensors of
the heating
system.
To prevent the warning / error message being shown again,
acknowledge by pressing the display once.
Status of the heating system
(Picture shows Alde Compact 3010)
Switch the heating system with the displayed values
on / off. If the heating system is switched on, the
button is green.
Set room temperature
Priority warm water
Heating timer is activated
Gas mode
Electro mode with 1 kW, 2 kW or 3 kW
Button to the menu "Operating mode" of the heating
system.
(Alde Compact 3010)
LED
Rectification
To reset the heat-
ing, switch the gas
mode off and then
on again.
To reset the 12 V
operating voltage,
switch the heating
off and then on
again via the mas-
ter switch.
Please contact the
respective service
partner.