CAUTION
• Ensure that the space around the left and right of the indoor unit is more than 12cm.
The indoor unit should be installed allowing a minimum clearance of 15cm from the ceiling.
• Use a stud finder to locate studs to prevent unnecessary damage to the wall.
A minimum pipe run of 3 metres is required to minimise vibration & excessive noise.
• The indoor unit should be installed on the wall at a height of 2.3 metres or more from the
floor.
• At least two of the directions A, B and C should be free from obstructions.
ATTENTION
• This illustration is for explanation and indication purposes only. The illustrations may be
different from the airconditioner you purchased.
• Copper lines must be insulated independently from each other.

INDOOR UNIT INSTALLATION

Correct orientation
of Installation Plate
90
09:04
Pagina 55
12 cm or more
Remote
Remote
Controller
Controller
Fig. 4
12 cm or more
Remote
Controller
Loop the
connective
cable
15 cm or more
Remote
Controller
Air outlet
4
55