Power supply
230V~50Hz
NOTE!
The supply voltage should be consistent with the rated voltage
of the air conditioner.
IMPORTANT
The device MUST always have an earthed connection. If the power supply is not earthed, you may
not connect the unit. The plug must always be easily accessible when the unit is connected. Read
these instructions carefully and follow the instructions.

Connect the cable to the indoor unit

1.
Remove the panel and Screw, then remove the window cover.
2.
Connect cables according to their marks to terminals.
3.
Wrap those cables not connected with terminals with insulation tapes, so that they will not touch any
electrical components.
4.
Fit the power cord clamp.
ATTENTION
Always make sure that the electrical connection cables from indoor to outdoor unit are correct
fitted, e.g. when a green electrical line is fitted to clamp with code "L" in the indoor unit the
other end of that same green electrical line should be connected to clamp with code "L" on the
outdoor unit.

Connect the cable to the outdoor unit

See fig. 21
1.
Remove the electric parts cover from the outdoor unit.
2.
Connect the connective cables to the terminals as identified with their respective matched numbers on
the terminal block of indoor and outdoor units.
3.
To prevent the ingress of water, form a loop of the connective cable as illustrated in the installation dia-
gram of indoor and outdoor units.
4.
Insulate unused cords (conductors) with PVC-tape. Make sure they do not touch any electrical or metal
parts.