Herunterladen Inhalt Inhalt Diese Seite drucken

Output; Electrical Data - JUMO PINOS L01 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8 Technical data
8.2

Output

Analog output – flow sensor
Attenuation
Scale start
Scale end
Behavior on error
Output signal
Switching output – flow switch
Output behavior
Switching point (Sp)
Release point (Rsp)
Switch-on delay
Behavior on error
Flow velocity
Repeatability
Measuring accuracy
Temperature drift
Response time
to flow change
Reference conditions
Medium
Medium temperature
Ambient temperature
Installation position
8.3

Electrical data

Voltage supply
Requirement
Electromagnetic compatibility
Interference emission
Interference immunity
Current consumption
26
Basic setting
0 s
10 cm/s
150 cm/s
3.4 mA
0(4) to 20 mA
Basic setting
Normally Open Con-
tact
75 cm/s
60 cm/s
0 s
switch off
Measuring range 10 to 150 cm/s
±2 % from measuring end value
±10 % from measuring end value
±0.2 %/K from measuring end value
4 to 10 s
Water
20 °C ±5 °C
20 °C ±5 °C
JUMO installation device
vertical riser pipe
rotation ±5 % away from preferred direction
DC 24 V ±10 %, SELV
The device must be equipped with an electrical circuit that
meets the requirements of EN 61010-1 with regard to "Limited-
energy circuits".
Acc. to DIN EN 61326-1
Class A – only for industrial use
Industrial requirement
Analog output - flow sensor: ≤ 200 mA
Switching output - flow switch: ≤ 400 mA
Setting range
0 to 99 s
10 to 150 cm/s
10 to 150 cm/s
0, 3.4 or 22 mA
0 to 20, 4 to 20, 20 to 0, 20 to 4mA
Setting range
N/O contact, N/C contact, window open-
ing function, window closing function
10 to 150 cm/s
10 to 150 cm/s
0 to 99 s
switch on, switch off

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis