function is indicated in the display by the text „TEST".
- The cycle is started by pressing the „Start" key.
- This function is completed following charging of the battery and automatic
transition to trickle voltage. This status is indicated by the message „VOLL" (full)
appearing in the display.
LC display indicators in test mode :
Selected channel
Batterysymbol
Symbol for
test mode
8. Manual Start/Stop
If necessary, charging and discharging processes can be stopped and started
manually, as required, when a battery is needed urgently, for example, and
must be used with the battery charge level as it is. Or, for example, to change
the process being applied to it.
- The charging process is stopped by pressing the „Start/Stop" key. When the
charging process has been stopped it can be started again from the beginning
by pressing the „Start/Stop" key again.

9. Channel Selection

The status of each charging channel can be checked at any time during operation
by switching the display indicator.
- Press the „Kanal" (channel) key to switch the channel displayed cyclically.
The channel currently selected is indicated in at the top left of the display.

10. Further Information

10.1. Automatic fan
The unit is equipped with a temperature-controlled fan which increases air
circulation and ensures even cooling of the power electronics when using several
of the charging channels simultaneously and high charging currents.
It is switched on and off automatically, and cannot be manually controlled.
Kanal
Spannung
Strom
T
E
S
Kapazität
T
34
Current cell voltage
V
Actual current, here
charge current
mA
Discharged capacity
mAh
in discharge process

Quicklinks ausblenden: