When operated with a conventional transformer, the
locomotive performs like a locomotive without a
decoder. However, the locomotive will begin to move
only after a control voltage of 5 to 5.5 Volts (DC) has
been reached, because the decoder requires a certain
minimum voltage simply to operate. Sound functio-
nality is possible during analogue operation and
begins at approx. 4.5V (DC).
– In DC operation trouble-free running with pulse-
Activate or deactivation the desired sound functions
via the CV13 (only possible with a digital system).
GB
The most important CV's
For the preset factory values please see the informa-
tion sheet enclosed with the locomotive or decoder.
Notice:
For the Lokmaus
values from 0 – 99 are programmable.
For the multi MAUS, the CV's from 1 – 256 and the
corresponding values from 0 – 255 are program-
mable.
10
8036231921.indd 10
Analogue Operation
width or phase-control controllers cannot be guar-
anteed.
Possible Settings in DCC Digital
®
, the CV's and the corresponding
CVs
1
Adress
(= short Adress)
2
Starting voltage
(lowest creep speed)
3
Acceleration time
(from standing to maximum speed)
4
Braking time
(from maximum speed to full stop)
5
Maximum speed
6
Average speed
(by middle driving stage)
7
Decoder Version Number
(only read! Readable only on rea-
ding-capable amplifiers/centres)
8
Reset Function
(Returns all values to the factory set-
tings; the manufacturer's ID is rea-
dable on reading-capable amplifiers/
centres)
13
Analogue Modes F1-F8
(
00 – no function in analogue mode)
01 – Function F1 02 – Function F2
04 – Function F3 08 – Function F4
16 – Function F5 32 – Function F6
64 – Function F7 128 – Function F8
Attention! Several things happen at
the same time when several functions
are activated via CV's in analogue
operation.
17
Long Address
+
(required: the long address is
turned on in accordance with the
18
CV29-setting)
Operation
value
01 – 99
01 – 75
00 – 64
00 – 64
00 – 64
00 – 64
08
00 – 255
100
– 9999
25.06.2009 12:36:59