Rotation axis board
4A
Rotation axis -
Communication
4B
Rotation axis - Current
4C
Rotation axis - Voltage
4D
Rotation axis - Board
temperature
4E
Rotation axis - Functioning
4F
Rotation axis - Direction
4G
Rotation axis - No speed
4H
Rotation axis - wrong
speed
4J
Rotation axis - Motor
temperature
Cooling unit alarms
5A
Cooling unit - Presence
5B
Cooling unit - Flow
Wire axis alarms
6A
Wire axis - Communication
6B
Wire axis - Current
6C
Wire axis - Voltage
Wire axis – Board
6D
temperature
6E
Wire axis - Functioning
6F
Wire axis - Direction
6G
Wire axis - Speed

5. Data acquisition

At the end of each welding, if the USB key is well plugged onto power source, a file is created with all
welding parameters, second per second: high current / low current / high voltage / low voltage / high
speed / low speed / high wire speed / low wire speed / real angle / torch gas flow / internal gas flow. This
file also contains the program number, machine, welding mode, tube diameter and thickness, welding
step, alarm and name of user.
System saves up to 1000 welding. After that, files are overwrited.
To remove USB key from power source, either switch it off or go to adjustment menu, USB, key and
press the bottom left button and wait until you see the message: USB key not connected.
To access data on computer, we supply software: « weldreport », available on the USB key. To install
and use this software, please refer to the pdf file onto the USB key: « WeldReport for SAXX200 –
Installation.pdf ».
Join
experience
Switch off the power source, wait 20s and switch it on. If alarm is
still active, contact AXXAIR.
Check name of machine into the program and into the serial
number plate of the machine connected.
Check the machine cables. It can be a problem onto the motor, or
speed/position sensor.
Electronic board temperature too high. Let it cool down.
Idem 4B/4C.
System detects a movement in the wrong direction.
Idem 4B/4C.
Idem 4B/4C.
Machine temperature too high. Let it cool down.
Cooling unit not detected whereas it is needed with the machine
you are using.
No flow or too low flow. Switch cooling connectors. Check that
hoses are not too much bended. Check quantity of liquid into the
tank.
Idem alarms 4 (rotation axis)
SAS au capital de 135 720 € - RCS Romans B414 581 363 – Code APE 2841 Z – Siret 414 581 363 00028 – TVA FR13414 581 363
330B Route de Portes Les Valence - ZI Les Bosses - 26800 Etoile sur Rhône
Tél: +33 475 575 070 - Fax: +33 475 575 080 - commerce@axxair.com - www.axxair.com