INNOVATIVE ORBITAL SOLUTIONS
If mode with wire :
Operator dynamic: zero by default, that means parameters will not be modifiable during the welding
(except in dynamic mode). If you put a value different from zero, all parameters will be modifiable
(even in welding mode and even with operator level) in the limit of the percentage you have entered.
Join
experience
SAS au capital de 135 720 € - RCS Romans B414 581 363 – Code APE 2841 Z – Siret 414 581 363 00028 – TVA FR13414 581 363
This window appears on the overlap
screen:
The parameter « Delay stop wire » is the
time between the beginning of the overlap
and the end of the wire feeding.
Wire back action: At the end of the wire
feeding, the wire goes back during the time
« wire back action ».
Downslope: This is the time during which
the welding current passes from the high
current
of
the
overlap
"Postwelding" current value.
Postwelding: It allows us to maintain a
current for a given time in order to prevent
any heat shock to the electrode or the bead
we have just made.
Postgas time: We continue to apply gas to
the end of the bead in order to prevent any
oxidation while the latter is cooling.
Save screen:
Total cycle time is displayed.
Welding energy is calculated as follow:
E = (k x U x I x 60) / V
E : J/mm
K : 0,7 (coef TIG)
U : in Volt (10+0,04 x I)
I : in Ampere
V : mm / min
This is the theoretical average energy of all
levels.
Press during 2s the saving button.
330B Route de Portes Les Valence - ZI Les Bosses - 26800 Etoile sur Rhône