9. Specifications
Specifications
Non-repeatability
EN
Signal noise
Temperature error at 0 ... 80 °C
Reference conditions
Settling time
Switch-on time
Ingress protection
Shock resistance
Service life
Short-circuit resistance
Reverse polarity protection
20
Measuring range ≤ 0.1 bar: ≤ ±0.2 % of span
Measuring range > 0.1 bar: ≤ ±0.1 % of span
≤ ±0.3 % of span
Typical: ≤ ±1 % of span
Maximum: ≤ ±2.5 % of span
Ambient temperature
Atmospheric pressure
Humidity
Power supply
Mounting position
Measuring range ≥ 0.4 bar: < 4 ms
Measuring range ≥ 0.05 bar: < 1 min
Measuring range ≥ 0.4 bar: < 15 ms
Measuring range ≥ 0.05 bar: < 1 min
The stated ingress protection only applies when plugged in using mating connectors that have
the appropriate ingress protection.
Angular connector DIN 175301-803 A
Angular connector DIN 175301-803 C
Circular connector M12 x 1
Cable outlet
500 g (IEC 60068-2-27, mechanical)
100 g at -40 °C
Measuring range > 0.1 bar: 100 million load cycles
Measuring range ≤ 0.1 bar: 10 million load cycles
S+ vs. 0V
U
vs. 0V
B
no reverse polarity protection with ratiometric output signal
WIKA operating instruction pressure transmitter, model A-10
15 ... 25 °C
860 ... 1,060 mbar
45 ... 75 % r. h.
DC 24 V
as required
IP65
IP65
IP67
IP67