Dräger X-plore
Singlefilter Full Face Masks
Preparation and filter attachment
1
Screw the Dräger X-plore Rd40 filter into the
mask body.
4
Fit harness over the head until the mask is in
position.
7
... tighten front strap if necessary.
www.draeger.com
6000
®
Donning the mask
2
Open straps as far as possible. Direct the mask
towards the face.
5
Tighten straps until the mask fits snug and
secure. First tighen both neck straps, ...
Performing seal checks: before every use!
8
Negative pressure test: Seal respiratory filters
with your palm and breathe in until a negative
pressure (suction) is generated. Hold your
breath for a mo-ment. The negative pressure
should be maintained. If not, readjust the face
piece and adjust the straps. Repeat test until a
successful for check is met.
First insert chin into the chinpiece of the mask.
... then both temple straps and ...
Warning: Beards in the sealing area of the mask can
cause leaks. Always make sure the mask forms a tight
seal and the filter is attached prior to entering a
hazardous atmosphere.
This poster is not a replacement for reading and under-
standing the instructions for use for the subject mask
and respective filter cartridge, both of which must be
read before using either item! Failure to do so could
result in sickness or death!
For further assistance concerning proper use, ask your
supervisor or call your local Dräger organization at
+49 451 882-0 or +1 800 922 5518.