6.1 Statement of the displayed values

Voltage of battery 1 (B1) or 2 (B2):
Display
Statement
less than 10.5 V
- battery is fully discharged;
switch off all consumers!
10.5 to 11.5 V
-
battery almost discharged;
reduce consumption!
11,5 to 12,5 V
-
normal operating state
12,5 to 12,8 V
-
battery fully charged, no load
connected
12,8 V to 14,2 V
-
battery is charged, no
significant load connected
more than 14.7 V
- Caution: high voltage! Should
not last for more than 1 h.
67
Statement of the displayed values
6.1
Solar power IS (charge current):
Display
Statement
0.0 to 0.1 A
- no charge current flowing,
cable breakage, too dark
0,1 to 1,0 A
-
normal charge current with
cloudy sky or modules partly
shadowed
1,0 to 20,0 A
-
charge current in sunshine,
level directly dependent
on size of solar module
Load current IL (discharge current):
Display
Statement
IL = 0,0 to 12A
- discharge current of the
consumers, level directly
dependent on the consumers
Statement of the displayed values