Technical Data

Digital Laser Rangefinder
Article number
Measuring range
Measuring accuracy (typically)
Lowest indication unit

Operating temperature

Storage temperature
Relative air humidity, max.
Laser class
Laser type
Laser beam diameter (at 25 °C) approx.
– at 10 m distance
– at 70 m distance
Batteries
Rechargeable batteries
Battery live, approximately
– Individual measurements
– Continuous measurement
Automatic switch-off after approx.
– Laser
– Measuring tool (without measurement)
Weight according to EPTA-Procedure 01/2003
Dimensions
Degree of protection (excluding battery compartment)
A) The working range increases depending on how well the laser light is reflected from the surface of the target (scat-
tered, not reflective) and with increased brightness of the laser point to the ambient light intensity (interior spaces,
twilight). In unfavourable conditions (e.g. when measuring outdoors at intense sunlight), it may be necessary to use
the target plate.
B) In unfavourable conditions (e.g. when measuring outdoors at intense sunlight or an insufficiently reflecting sur-
face), the maximum deviation is
must be taken into account.
C) In the continuous measurement function, the maximum operating temperature is +40 °C.
D) Fewer measurements are possible when using 1.2 V rechargeable batteries as compared with 1.5 V batteries.
Please observe the article number on the type plate of your measuring tool. The trade names of the individual meas-
uring tools may vary.
The measuring tool can be clearly identified with the serial number 20 on the type plate.
Bosch Power Tools
±
10 mm per 70 m. In favourable conditions, a deviation influence of
3 601 K16 60.
– 10 °C...+50 °C
– 20 °C...+70 °C
635 nm, <1 mW
4 x 1.5 V LR03 (AAA)
4 x 1.2 V KR03 (AAA)
59 x 100 x 32 mm
IP 54 (dust and splash water protected)
1 609 929 R53 | (23.7.08)

English | 19

DLE 70
Professional
A)
0.05 – 70 m
± 1.5 mm
B)
1 mm
C)
90 %
2
6 mm
42 mm
D)
30000
D)
5 h
20 s
5 min
0.18 kg
±
0.05 mm/m