• Now push the button "FUNC" again. The minutes for the start time will now flash in the display.
Push the button "+/ON" or "-/OFF" to set the proper number of minutes.
• Now push the button "FUNC" again. The hours for the end time will now flash in the display.
Push the button "+/ON" or "-/OFF" to set the proper number of hours.
• Now push the button "FUNC" again. The minutes for the end time will now flash in the display.
Push the button "+/ON" or "-/OFF" to set the proper number of minutes.
• Now push the button "FUNC" again. The left part of the display now shows the "desired
temperature". After a few seconds, the electronics switch to the consumption values of a con-
nected device. The right part of the display shows the selected connection "Radio measuring
display for radio measuring socket" and the current temperature and time.
• To activate temperature monitoring by programmed time windows, push the button "-/OFF",
until the display shows "Auto". The radio measuring display/thermostat will now monitor the
set temperature in the programmed time windows.
Example 1:
You have chosen the operating mode "Cooling" and temperature 22 °C for the time from
8:00 AM to 12:00 PM. An air conditioning unit is connected to the selected switching socket.
When the temperature in the room rises above the set "target temperature" of 22 °C for a certain
time during the programmed time window, the radio measuring display/thermostat will send the
signal "activate" to the chosen radio switching socket.
The air conditioning unit will start to work. The left display will now alternate between the mains
voltage in Volt (V) and the current demand of the connected device in Ampere (A). Additionally,
the power of the connected device in Watt (W) is displayed below this. The very bottom of the
display shows the power used kW/h.
If the room temperature permanently drops below the "target temperature" (here: 22 °C), the air
conditioning unit is switched off again. To prematurely deactivate this temperature monitoring by
time window, push the button "FUNC" repeatedly until "Cancel" appears in the display.
If an automatic temperature monitoring by time windows is deactivated prematurely
(Cancel), the switching condition that was active at deactivation will be preserved.
Therefore, you must switch off any activated switching sockets manually after deacti-
vation (see chapter 9).
If the radio measuring switching socket is switched on and the time window ends, the
radio measuring switching socket is switched on independently of the room tempera-
ture at the expiration of the end time.