Replace the disposal bag
Illustration
Release and remove the suction head.
Put the disposal bag over.
Pull the opening of the disposal bag out
toward the back over the suction sup-
port and seal it tightly.
Tightly seal the disposal bag with clo-
sure strips underneath the opening.
Remove disposal bag.
Dispose of the disposal bag according
to the local provisions.
Attach the new disposal bag.
Pull disposal bag over the container.
Insert and lock the suction head.
Replace membrane filter
Illustration
Release and remove the suction head.
Remove the membrane filter.
Pull the new membrane filter over the
container edge.
Insert and lock the suction head.
Cleaning the electrodes
Release and remove the suction head.
Clean the electrodes with a brush.
Insert and lock the suction head.
Troubleshooting
Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
Note:In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.
Suction turbine does not run
Check cables, plugs, fuse, socket and
electrodes.
Turn on the appliance.
Suction turbine turns off
Empty the container.
Suction turbine does not start again
after the container has been
Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
Clean the electrodes as well as the
space between the electrodes with a
brush.
Suction capacity decreases
Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
Replace the full paper filter bag.
Replace the filled disposal bag (option).
Ensure the filter cover properly locks
into place.
Clean or replace the membrane filter
(special accessory) under running water.
Replace the flat pleated filter.
Dust comes out while vacuuming
Check for proper installation of the flat
pleated filter.
Replace the flat pleated filter.
Automatic shut-off (wet vacuum
cleaning) does not react
Clean the electrodes as well as the
space between the electrodes with a
brush.
Continuously check the filling level in
case of non-conductive liquid.
Set the rotary switch to the correct suc-
tion hose cross-section.
If the paper filter bag is full and the min-
imum volume flow is fallen short of it
has to be replaced.
If the disposal bag (option) is full and
the minimum volume flow is not
achieved, this filter has to be replaced.
7
-
EN
emptied
Horn sounds
23