Replace the disposal bag
Illustration
 Release and remove the suction head.
 Put the disposal bag over.
 Pull the opening of the disposal bag out
toward the back over the suction sup-
port and seal it tightly.
 Tightly seal the disposal bag with clo-
sure strips underneath the opening.
 Remove disposal bag.
 Dispose of the disposal bag according
to the local provisions.
 Attach the new disposal bag.
 Pull disposal bag over the container.
 Insert and lock the suction head.
Replace membrane filter
Illustration
 Release and remove the suction head.
 Remove the membrane filter.
 Pull the new membrane filter over the
container edge.
 Insert and lock the suction head.
Cleaning the electrodes
 Release and remove the suction head.
 Clean the electrodes with a brush.
 Insert and lock the suction head.
Troubleshooting
Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
Note:In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.
Suction turbine does not run
 Check cables, plugs, fuse, socket and
electrodes.
 Turn on the appliance.
Suction turbine turns off
 Empty the container.
Suction turbine does not start again
after the container has been
 Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
 Clean the electrodes as well as the
space between the electrodes with a
brush.
Suction capacity decreases
 Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
 Replace the full paper filter bag.
 Replace the filled disposal bag (option).
 Ensure the filter cover properly locks
into place.
 Clean or replace the membrane filter
(special accessory) under running water.
 Replace the flat pleated filter.
Dust comes out while vacuuming
 Check for proper installation of the flat
pleated filter.
 Replace the flat pleated filter.
Automatic shut-off (wet vacuum
cleaning) does not react
 Clean the electrodes as well as the
space between the electrodes with a
brush.
 Continuously check the filling level in
case of non-conductive liquid.
 Set the rotary switch to the correct suc-
tion hose cross-section.
 If the paper filter bag is full and the min-
imum volume flow is fallen short of it
has to be replaced.
 If the disposal bag (option) is full and
the minimum volume flow is not
achieved, this filter has to be replaced.