Herunterladen Inhalt Inhalt Diese Seite drucken

LEMET BUFOR Bedienungsanleitung Seite 9

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

- During the warranty period, the user is entitled to free repairs of any defects in the boiler due to causes
associated with the product. In Poland, the warrantor undertakes to consider a reported defect and, if it is
found that the defect is covered by the warranty, to eliminate the defect within 14 days from the date of
receipt of the defect report. In other countries, the time limit for elimination of the defect depends on the
provisions of law in force in the specific country or on the warranty granted by the authorized
distributor/importer.
- Repair warranties do not apply to the activities specified in the instruction which must be performed by the
user at his or her own expense.
- The warranty does not cover defects caused by improper use, performance of repairs and modifications by
unauthorized person, as well as installation and maintenance performed not in compliance with this operating
instruction.
- The warranty does not include damage caused by random events (storms, fires, floods).
- If a defect occurs, the device should not be uninstalled and the defect must be reported to the warrantor. One
must keep the sales document for the boiler as well as the warranty card stamped at the point of sales, for
verification by the service company.
- If there is no free access to the boiler for maintenance, repairs, or replacement, the warrantor or the service
company indicated by the warrantor will not accept any liability for any inconveniences or costs associated
with disassembly of any installed elements or systems.
- The repair method will be determined by the warrantor.
- The warrantor will not accept any liability for improper operation of the safety valve or for errors in the
system, e.g. lack of the water pressure reducing valve in the cold water supply system.
- In matters not regulated in these terms of warranty, local reg+ulations apply.
- Use of the boiler without a properly working safety valve and all mechanical damages will lead to loss of the
warranty. Any damages caused by an improperly working safety valve (usually a "bloated" tank or cracked
cylinder) are not covered by the warranty.
- Use of the boiler in water supply systems with pressure higher than the pressure specified by the
manufacturer without a properly working water pressure reducing valve will lead to loss of the warranty.
- The manufacturer reserves the right to modify the parameters of newly manufactured devices without notice.
- The basis for any warranty repairs is a properly filled out warranty card stamped by the point of sales and the
installer, without any corrections, as well as the sales document. A copy of the warranty card may be issued
only by the warrantor after the required documents have been submitted.
- The warranty does not exclude, limit, or suspend the buyer's rights under the regulations on the implied
warranty for defects in the sold item.
- The manufacturer of the boiler will not accept any responsibility for the quality of water (the chemicals
contained in the water, the scale, and the oxygen content) and the associated difficulties in the use of the
boiler.
- Performance of repairs and modifications by unauthorized persons will lead to loss of the warranty.
- Any and all mechanical damage to the tank (boiler) will lead to loss of the warranty.
- In the event of unjustified call on the warrantor to perform a repair, the incurred costs will be borne by the
user.
- The equipment must be stored in non-freezing temperatures, in dry indoor spaces that are free of dust and
aggressive substances, and must be protected against mechanical, chemical and thermal damage.
EN
9. FAULTS AND THEIR DISPOSAL
ITEM
PROBLEM
NO.
The safety valve is stuck or clogged
The safety valve is not opening.
1
with scale.
1. The contact surface of the valve is
dirty or damaged.
The safety valve is leaking
2. Residues of sealing materials (Teflon
2
(the water drips all the time).
tape, packing) under the valve head.
3. Excessive water pressure in the water
supply system.
- 19 -
SOLUTION
POSSIBLE CAUSE
Clean or replace the valve.
1. Clean or grind the contact surface of
the safety valve.
2. Check and remove any sealing
materials from the safety valve.
3. Reduce the water pressure by installing
a reducing valve.
2.7.
TYP / type / Typ: BUFOR ; 200MG, 300MG, 400MG, 500MG, 600MG, 800MG, 1000MG, 1500MG, 2000MG, 2500MG,
3000MG, 4000MG, 5000MG, bez wężownicy / without coil / ohne Wärmetauscher,
C
Widok z góry / view from up / Blick von oben
D
OZ
A
CT
KPx4 szt. / pcs. / tlg.
KPx2
G
CT
KPx2
F
CT
KPx2
E
KP
CT
KPx2
B
OZ
CT
* - TYP / type / Typ: 200MG, 300MG,
0
0
A
B
16.200
MG
-0 /
16.200MGN-0
1750
165
16.300MG-0 / 16.300MGN-0
1500
195
16.400MG-0 / 16.400MGN-0
1632
235
16.500MG-0 / 16.500MGN-0
1660
230
16.600MG-0 / 16.600MGN-0
1740
235
16.800MG-0 / 16.800MGN-0
1840
315
16.1000
MG
-0
/ 16.1000MGN-0
2170
250
16.1500MG-0 / 16.1500MGN-0
2095
375
16.2000MG-0 / 16.2000MGN-0
2105
375
16.2500MG-0 / 16.2500MGN-0
2595
375
16.3000MG-0 / 16.3000MGN-0
2596
375
16.4000MG-0 / 16.4000MGN-0
2819
405
16.5000MG-0 / 16.5000MGN-0
2770
455
Symbol - izolowane / Symbol - isolated / Symbol - isoliert
Symbol - nie izolowane / Symbol - not isolated
Symbol - nicht isoliert
Pojemność nominalna / Nominal capacity / Nennvolumen
Maksymalna temperatura i ciśnienie robocze zbiornika
Water tank maximum working temperature and pressure
Tank Maximale Betriebstemperatur und Druck
Rodzaj Izolacji / type of insulation / Art der isolierung
Waga / weight / Gewicht
Min. grubość dennicy / Min.
of bottom / Min.
von unten
Min. grubość płaszcza / Min.
of cylinder / Min.
Zylinder
OZ
KPx5 szt. / pcs. / tlg.
CTx4 szt. / pcs. / tlg.
O
100
Króciec przyłączeniowy / Connection stub pipe
Anschlussstutzen
Odpowietrzenie zbiornika / Tank air went
Tankentlüftungs
Tuleja na czujnik temp. / Pipe for temp. sensor
Rohr für Temperaturfühler
C
D
E
F
G
600
400
625
1085
1545
750
550
551
908
1265
800
600
610
980
1355
850
650
621
1013
1405
900
700
645
1055
1465
990
790
725
1135
1545
990
790
790
1330
1870
1200
1000
820
1345
1755
1350
1150
820
1345
1755
1350
1150
985
1600
2205
1450
1250
985
1600
2205
1600
1400
1065
1730
2385
1800
1600
1065
1680
2285
L
200
300
400
500
600
800
1000
1500
2000
2500
95
O
C / 3 Bar
typ
zdejmowana / removable / abnehmbar
kg
58
66
85
87
108
117
125
212
247
292
mm
2,5
2,5
3,0
2,5
3,0
2,5
2,5
3,5
4,0
4,0
mm
2,5
2,5
2,5
2,5
2,5
2,5
2,5
3,0
3,0
3,0
G 6/4" W/F
G 1" W/F*
G 6/4" W/F
G 1/2" W/F
M
100
100
100
150
150
150
150
150
150
150
150
150
150
3000
4000
5000
380
495
600
4,0
5,0
5,0
3,0
4,0
4,0
- 8 -

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Spiro

Inhaltsverzeichnis