Input logic
0 * PNP operating point 11 V
1
NPN operating point 11 V
2
PNP operating point 5 V
3
NPN operating point 5 V
4
PNP operating point 2.5 V
5
NPN operating point 2.5 V
Reset main counter
0 * Automatic reset, externally static
1
Automatic reset, externally differentiated
2
Externally static
3
Externally differentiated
Function, signal input 9 (stop/hold)
0 * Stop
1
Hold
2
Keylock
3
Operating hours counter on/off
4
Print (for version with interface only)
Output logic for digital outputs
0 * Both outputs as normally open contacts
1
P1 normally closed, P2 normally open
2
P1 normally open, P2 normally closed
3
Both outputs as normally closed
Output time P1
0,0
*
Data in seconds (tol. -0.01 s, range 00.02 – 99.99 s)
00.25
00.25 s
99.99
Maximum pulse time
LAtCH = continuous signal (
Output time P2
0.0
*
Data in seconds (tol. -0.01 s, range 00.02 – 99.99 s)
00.25 *
00,25 s
99.99
Maximum pulse time
LAtCH = continuous signal (
Acceptance of presets P1, P2, SC
0 * Effective immediately
1
On reset
P1, P2 and SC active
0 * Only in plus counting range
1
In plus and minus counting range
Function key assignment
0 * No function
1
XP
2
P1
3
P2
4
SC
5
6
www.checkline.eu