System response
Accuracy class:
0.2 resp. 0.4 at applications with
phase-shift
Energy meter:
1.0 according to IEC 1036
(0.1 Ir ≤ I ≤ 1.5 Ir)
Duration of the
measurement cycle:
Depending on measured variable
and programming
Response time:
Approx. 1 ... 2 times the measure-
ment cycle and 1...2 s
Infl uencing quantities and permissible variations
Acc. to EN 60 688
Electrical safety
Protection class:
II
Enclosure protection:
IP 40, housing
IP 20, terminals
Overvoltage category:
III
Insulation test:
Input voltage:
Input current:
Output:
Power supply:
Surge test:
5 kV; 1.2/50 μs; 0.5 Ws
Test voltage:
50 Hz, 1 min. according to
EN 61 010-1
5550 V, inputs versus all other circuits
as well as outer surface
3250 V, input circuits versus each
other
3700 V, power supply versus outputs
and SCI as well as outer surface
490 V, outputs and SCI versus each
other and versus outer surface
Power supply
Voltage:
Acc. to type label
DC, AC 24... 60 V
DC, AC 85...230 V
Consumption:
≤ 9 W resp. ≤ 10 VA
32
Programming connector on transducer
Interface:
DSUB socket:
CTS
RTS
DSR
Installation data
Housing:
Housing material:
Mounting:
AC 400 V
AC 400 V
DC 40 V
Mounting position:
AC 400 V
DC 230 V
Terminals
Type:
Max. wire gauge:
Ambient conditions
Nominal range of use
for temperature:
Operating temperature: – 10 to + 55 °C
Storage temperature:
Annual mean
relative humidity:
Altitude:
Indoor use statement!
RS 232 C
9-pin
5
9
GND
DTR
The interface is electrically insula-
TXD
ted from all other circuits.
RXD
6 1
Housing T24
Dimensions see section "11. Di-
mensional drawings"
Lexan 940 (polycarbonate),
flammability class V-0 acc. to
UL 94, self-extinguishing, non-
dripping, free of halogen
For snapping onto top-hat rail
(35 × 15 mm oder 35 × 7.5 mm) acc.
to EN 50 022
or
directly onto a wall or panel using
the pull-out screw hole brackets
Any
Screw terminals with wire guards
≤ 4,0 mm
2 × 2.5 mm
0...15...30...45 °C
(usage group II)
– 40 to + 85 °C
≤ 75%
2000 m max.
2
single wire or
2
fi ne wire

Quicklinks ausblenden: