Herunterladen Inhalt Inhalt Diese Seite drucken

Interconnecting Several Devices (Master/Slave Operation); Dmx Operation - EuroLite CRT-190 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für CRT-190:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

S008
S009
S010
S011
S012
S013
S014
S015

Interconnecting several devices (master/slave operation)

Several devices may be interconnected (max. 32). Then all slave units can be synchronized and controlled
with the master unit without the need for a DMX controller. The devices must be set to the corresponding
operating modes.
1
Configure all slave units before connecting the master unit: Press the MENU button so many times until
SLAu is indicated in the display. Confirm with the ENTER button.
2
Connect the DMX output of the master unit to the DMX input of the first slave unit. Then connect the
DMX output of the first slave unit to the DMX input of the second slave unit, etc. until all units have been
connected in a chain. Make sure the master unit is the first in the chain. Do not connect a DMX controller
to the DMX input of the master unit.
3
Set the master unit to the desired operating mode. The interconnected devices will now operate in sync.

DMX operation

DMX512 connections
A DMX512 data link is required in order to control the device via DMX. The device provides 3-pin XLR
connectors for DMX connection.
1
Connect the output of your DMX controller to the DMX input DMX IN of the light set with a DMX cable.
2
Connect the DMX output DMX OUT of the light set to the DMX input of the next unit in the chain. Always
connect one output to the input of the next unit until all units are connected.
3
At the last unit, the DMX cable has to be terminated. Plug the terminator with a 120 Ω resistor between
Signal (–) and Signal (+) in the DMX output of the last unit.
4
If the cable length exceeds 300 m or the number of DMX devices is greater than 32, it is recommended
to insert a DMX level amplifier to ensure proper data transmission.
XLR connection:
Setting the DMX starting address
For operation with a controller with DMX512 protocol, the device is equipped with 7 control channels. To be
able to operate the device with a DMX controller, the DMX starting address must be set for the first DMX
channel. The starting address depends upon which DMX controller is being used. Please refer to the
controller's documentation.
1
Press the MENU button so many times until Addr is indicated on the display. Confirm with the ENTER
button.
2
Now the display indicates the menu item for the DMX start address d***. Use the buttons UP and DOWN
to set the address. Confirm with the ENTER button.
3
The SIGNAL indicator will light up when DMX signals are being received.
LED groups2 and 3 on
LED groups2 and 4 on
LED groups3 and 4 on
LED groups1, 2 and 3 on
LED groups1, 2 and 4 on
LED groups1, 3 and 4 on
LED groups2, 3 and 4 on
All LEDs on
20/24
00114933, Version 1.2