Herunterladen Diese Seite drucken

Hendi 202500: 230/240 VAC 2000 W Gebrauchsanweisung Seite 7

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

After use / Drain the water
Turn off the equipment by unplugging it from the mains supply.
Remove the trays.
Allow the water to cool down.
Only for Bain marie 150 and Bain marie 11l: poor the water out of the container
Place a bucket under the drain pipe.
Open the drain. The water will drain from the container.
When the water has drained from the container, close the drain.
COMMENT:
If the water being drained is dirty, leave the tap open and rinse the appliance with clean
water.
Maintenance
Before cleaning, always unplug the equipment from the mains supply.
Never immerse the bain-marie in water or other cleansing agents.
Clean the bain-marie with a damp cloth.
Do not use aggressive or caustic cleansing agents.
Wherever possible, avoid water coming into contact with electrical components.
Regularly descale the bottom of the water container.
Faults:
Fault
Appliance
does not do
anything
Appliance
does not
reach the set
temperature
If in doubt, contact your supplier.
Overload circuit breaker tripped
This appliance is fitted with an automatic overload circuit breaker.
To make the appliance operational again, first allow the appliance to cool down, then fill
with additional water.
Symptom
Orange lamp does not
light, the green lamp does
not light and the red lamp
does not light
The green lamp does not
light
Cause
Possible solution
No mains voltage
Check the power supply.
Thermostat
Replace the thermostat.
defective
Element defective Replace the element.
6

Werbung

loading