If the display is switched on and it is not attached to
the logger the opposite appears in the display.
The display switches off automatically after 5 s.
- - - - - - - -
O F F
Attach the display to the logger (ensure correct
connection) and switch on. Wait on the segment test.

Menu item: "Current measured value"

A A c c L L
- -
Select the menu item required:
("Act", "Cont", "Prnt", "Info")
Select the channel required.
1
2 2 8 8 . . 0 0
The current measured value is displayed.
If the limit value has been exceeded this is indicated.
%
2 2 5 5 . . 8 8
°C
Normally it can be assumed that a logger is program-
med.
When switched on the following data is called up
once:
* The min/max values
Channel
* The limit values for each socket and their channels
- Information as to whether the limit values have
been exceeded
Example:
- The current measured value of the socket channels
Logger 171-6
and information as to whether the current measu-
- Ext. probe - channel 1
red values also exceed the limit value
Combined %RH/°C
- Current meas. values
*) Information can be called up via menu item 4
28 %RH and 25.8 °C
4

Measuring

Current measured value

Display 1: Measurement channel
1 1 8 8 . . 0 0
i
°
C
If there are measurement channels on one socket
(humidity and temperature), the humidity value is dis-
played in the first line and the temperature value in
the second line. Otherwise only the first line will be
used.
Example:
Logger 171-1
- Logger is currently measuring
- The internal temperature probe has a measured
value of 18.0 °C
Contact switch (on request)
1 1 1 1 1 1 1 1
1
If a contact switch is used it is only indicated whether
it is closed (display 1111) or open (display 0000).
Example:
Logger 171-1
- Logger is currently measuring
- Contact switch on socket 1 is closed

Display: Probe failure

1
- - - - - -
In the case of probe failure or of a channel which was
programmed but to which a probe was not connected,
%
this symbol is shown with the appropriate unit.
°C
2 2 5 5 . . 8 8
Example:
Logger 171-6
- There is no measured value in the humidity channel.

Display: Exceeding the measuring range

8 8 8 8 . . 0 0
1
%
Example:
2 2 5 5 . . 8 8
°C
Upper limit of the humidity measuring range at
socket 1 was exceeded.
1 1 0 0 . . 0 0
1
Example:
%
Lower limit of the humidity measuring range
2 2 5 5 . . 8 8
°C
at socket 1 was exceeded.
1
%
°C
- - - - - -
Measuring
Current measured value
Example:
Measuring range of the temperature
channel at socket 1 was exceeded.
5