5 Specifications

BlueSolar charge controller
Battery voltage
Maximum battery current
Nominal PV power, 12V 1a,b)
Nominal PV power, 24V 1a,b)
Max. PV short circuit current 2)
Automatic load disconnect
Maximum PV open circuit voltage
Peak efficiency
Self consumption
Charge voltage 'absorption'
Charge voltage 'float'
Charge algorithm
Temperature compensation
Continuous/peak load current
Low voltage load disconnect
Low voltage load reconnect
Protection
Operating temperature
Humidity
Maximum altitude
Environmental condition
Pollution degree
Data communication port
Colour
Power terminals
Protection category
Weight
Dimensions (h x w x d)
Safety
1a) If more PV power is connected, the controller will limit input power
1b) PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter minimum PV voltage is Vbat + 1V.
2) A PV array with a higher short circuit current may damage the controller.
MPPT 100/15
12/24 V Auto Select
Yes, maximum load 15A
14,4V / 28,8V
13,8V / 27,6V
multi-stage adaptive
-16mV / °C resp. -32mV / °C
11,1V / 22,2V or 11,8V / 23,6V
or BatteryLife algorithm
13,1V / 26,2V or 14V / 28V
or BatteryLife algorithm
Battery reverse polarity (fuse)
Output short circuit / Over temperature
-30 to +60°C (full rated output up to 40°C)
100%, non-condensing
5000m (full rated output up to 2000m)
Indoor Type 1, unconditioned
See the data communication white paper on our website
ENCLOSURE
Blue (RAL 5012)
6mm² / AWG10
IP43 (electronic components)
IP22 (connection area)
100 x 113 x 47mm
STANDARDS
EN/IEC 62109
15A
220W
440W
20A
100V
98%
10mA
(adjustable)
(adjustable)
15A / 50A
PD3
VE.Direct
0,4kg

Quicklinks ausblenden: