Dispensing
5.3

Adjusting the Dispensed Quantity

5.3.1

Time Controlled Mode

This mode of operation is used for spot shaped wetting or drop dispensing.
• With buttons
time to 0.50 s. The indication of the dispensing
time in the digital display begins blinking.
• With the pressure regulator set the
dispensing pressure to 0.5 bar
(approx. 7 PSI).
If the dispensed quantity is too small:
• Increase the dispensing pressure. After this
check the dispensed quantity.
Repeat this sequence until the desired
dispensed quantity is roughly achieved.
When the desired dispensed quantity is roughly achieved:
• Set the exact dispensed quantity by changing the dispensing time with button
• Press the footswitch to check the dispensed quantity.
Storing of the dispensed quantity setting for subsequent dispensing:
• Press button
If the desired dispensed quantity is not achieved:
• With a larger (or smaller) dispensing needle, repeat the steps of this section.