Herunterladen Inhalt Inhalt Diese Seite drucken

Loctite 97007 Bedienungsanleitung Seite 12

2 l-halbautomatisches dosiersystem
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2
Description
19
18
17
C O N T
C O N T
16
15
of the dispensing time [s] in the digital display begins to blink. The dispensing time is adjustable
from 0.01 to 99.9 s.
Buttons for switching from time controlled mode to continuous mode.
With the simultaneous pressing of the buttons for more than 0.5 seconds, an operating mode
change takes place to the Continuous mode. In the display, "con" appears. The lighting of the
LED "CONT." indicates Continuous mode.
During dispensing, the elapsed dispensing time is indicated in the digital display beginning each
time with 0.00 s. The last dispensing time remains displayed until the next start.
– Switching back to time controlled mode without storage of the dispensing time by renewed
pressing of button
is blinking.
– Switching back to time controlled mode with storage of the dispensing time by pressing
button
18
Digital Display
Three-figure Display of the dispense time [s].
19
LED "CONT"
The lighting of the red LED "CONT" indicates Continuous mode.
12
or
. The LED extinguishes. In the digital display, the dispensing time
. The LED extinguishes. The indicated dispensing time is stored.
15
Button
Button for the storage of the new values set for the
dispensing time [s].
When the indication of the dispensing time [s] in the
digital display blinks, the indicated dispensing time
is stored by pressing button and the display stops
blinking.
16
Button
Button for filling the product feedline. In both modes
the product is dispensed as long as button is
pressed.
– In time-controlled mode, the dispensing time is
not changed.
Buttons
17
Buttons for changing the dispensing time for a
dispensing sequence.
When button
or
is pressed, the display

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

970089700997010

Inhaltsverzeichnis