FUMES DISCHARGE
(only intended for personnel qualified to assemble the hood)
The hood supplied with an 800 m
operating: refer to the instructions
When the kitchen hood is used simultaneously with other appliances that use gas or other fuels, the room must have sufficient ventila-
tion, in accordance with regulations in force.
The active carbon filters in this version are to be removed. Refer to the instructions
Deviation for Germany: when the kitchen hood is used at the same time as appliances that are powered by energy other than electricity, the negative pressure
in the room must not exceed 4 Pa (4 x 10-5 bar).
ASSEMBLY INSTRUCTIONS
Before installing the hood, make sure the structure in which it will be fixed can safely support the device: the weight of the hood, in
various configurations, is reported in the technical sheets at the beginning of this booklet.
B
Phase
page 7
• Drill the hole intended for recessing (for the size of the hole, see the technical sheets at the beginning of this booklet).
C
Phase
page 7
• Only for the external exhaust (suction) version with an 800m
(ERM) is installed, remove it (Fig.
previously removed fitting (ERM) back in (Fig.
D
Phase
page 7
• Insert the hood at the bottom of the wall unit (Fig.
3
-
).
E
Phase
page 8
• Open the perimeter suction panel (see instructions
hood at the bottom of the wall unit (Fig.
Make sure that the springs (MO) grip the bottom of the wall unit.
Avoid using force to block the hood: use the provided tool as indicated.
• Make sure that the hood is well secured to the structure and close the perimeter suction panel.
EXTERNAL EXHAUST HOOD VERSION (SUCTION)
• Connect the hood's air outlet fitting to the external exhaust with a suitable pipe (Phase
HOOD VERSION WITH INTERNAL RECIRCULATION (FILTERING)
• Check that the active carbon filters are assembled onto the hood; if not, install them as instructed
• If installed, remove the fitting (ERM) and any check valve (M) installed on the hood's air outlet fitting (perform, in reverse order, the oper-
ation described in the instructions
EXTERNAL EXHAUST HOOD VERSION (SUCTION)
In this version, the kitchen fumes and vapours are conveyed outside through an exhaust pipe.
The air outlet fitting that extends from the upper part of the hood must be connected with the pipe that conducts
the fumes and vapours to an external output.
Do not connect the equipment to discharge pipes of fumes produced from combustion (for example boil-
ers, fireplaces, etc) and you are to comply with the regulations in force regarding external air discharge.
The fumes outlet pipe must have:
- a diameter not less than that of the hood fitting;
- a slight slope downwards (drop) in the horizontal sections to prevent any formation of condensation from flowing
back to the hood;
- the minimum required number of bends;
- minimum required length (long pipes with various bends can reduce suction performance of the hood and trigger
vibrations of the check valve).
If the fumes outlet pipe passes through cold environments such as attics, etc., it is possible that water condensation
forms due to sudden changes in temperature. In this case, you are required to insulate the pipes.
3
/h motor is equipped with a check valve whose function is to prevent external air exchange when the hood is not
C
on page 7 for assembly.
HOOD VERSION WITH INTERNAL RECIRCULATION (FILTERING)
In this model, air passes through the active carbon filters to be purified and is then recycled into the kitchen environ-
ment.
Check that the active carbon filters are assembled onto the hood, if not, install them as indicated in the in-
L
structions
on page 9.
If the hood is set up with a filtering version, the check valve must not be assembled: remove it if it is on the air outlet
fitting of the motor (carry out operations described in the instructions
If you wish to install the filtering version hood, drill a hole in the wall structure where it will be moun-
ted, of a suitable size to allow purified air to exit the structure. This hole should be connected to the
hood's air outlet fitting with a suitable pipe to protect the inside of the structure from humidity and
residues of fat particles.
(only intended for personnel qualified to assemble the hood)
1
), install the check valve (M) as illustrated in the figures (Fig.
6
).
1
): the springs (MO) open and temporarily support the hood on the structure (Fig.
H
page 9), tighten the 4 screws (V1) to open the springs (MO) (Fig.
3
)..
C
page 7).
L
on page 9 for removal.
3
/h motor: if you wish, install the check valve (M); if the fitting
F
page 8).
L
20
C
on page 7 in reverse order).
2
3
4
5
-
-
-
) and put the
2
) and block the
page 9.
2