Operation
Description of the Appliance
1 Power cord with plug
2 Drum edge holder
3 Locking valve
4 O ring
5 Housing bowl for level switch (SBP
3800)
6 Housing cover for level switch (SBP
3800)
7 Hose coupling
8 Pressure hose
9 Hose clamp
10 Level sensor
11 Level switch attachment
12 Carrying handle
13 Hose connection G
for hose coupling
14 Foam filter
15 Filter basket
Preparing the drum pump operation
 Screw the hose connection on to the
pump
 Connect the hose connection to the
hose coupling of the drum edge holder.
Illustration
SBP 3800 only
 Screw the housing bowl and the O-ring
onto the drum edge holder.
 Place the level switch into the housing
bowl.
 Press the housing cover down onto the
housing bowl until it locks.
Illustration
 Slide the drum edge holder onto the
container edge until it is properly seat-
ed.
Illustration
 Place the pump on a stabil surface in
the liquid to be transported. Immerse it
using a rope tied to the handle or hang
it into the container by the hose.
The suction area should not be blocked
fully or partially through the impurities.
14
/
(24.4 mm)
3
4
Illustration
 Close locking tap (arrow horizontal).
Different uses of the level switch
Illustration
 In automatic operation, set the required
switching height by clamping the level
switch cable into the stopper.
Illustration
 In manual operations mode, align the
level sensor upward (cable pointing
downward). Tip: Push the cable of the
level sensor like a loop through the han-
dle.
Note:
When using the SBP 3800, the level switch
can be placed inside the housing bowl (Fig-
ure 1).
Preparing the immersion pump op-
 Screw the hose connection G 3/4 (24.4
mm) for the 3/4" (19 mm) hose onto the
pump (not included in the delivery).
 Slide the hose onto the hose connec-
tion and fasten it with an appropriate
hose clamp.
Note:
A short hose and a large hose diameter
yield a high volume.
Illustration
 In automatic operation, set the required
switching height by clamping the level
switch cable into the stopper.
Illustration
 In manual operations mode, align the
level sensor upward (cable pointing
downward). Tip: Push the cable of the
level sensor like a loop through the han-
dle.
– 3