3. Technical data and intended use

3. Technical data and intended use
Pressure limitation
Model 73X.51/31:
Table 1: Max. working pressure / Overpressure safety maximum in bar
Pressure ranges
0 ... 16 to 0 ... 40 mbar
0 ... 60 to 0 ... 250 mbar 6
0 ... 400 mbar
0 ... 0.6 bar
0 ... 1 bar
0 ... 1.6 bar
0 ... 2.5 to 0 ... 25 bar
Model 73X.14:
Process connection
In accordance with the general technical regulations for pressure gauges
(i.e. EN 837-2 „Selection and installation recommendations for pressure
gauges").
When screwing gauges in, the force required for this must not be applied
through the case, but rather through the spanner flats (using a suitable tool)
provided for this purpose on the square shaft of standard connections.
Temperature effect
When the temperature of the measuring system deviates from the reference
temperature (+20 °C): max. ±0.5 %/10 K of full scale value
IP Ingress protection
IP 54 per EN 60 529 / IEC 60 529
(with liquid filling IP 65)
WIKA Operating instructions pressure gauges Model 7 per ATEX
Steady:
full scale value
Fluctuating:
0.9 x full scale value
Working pressure max.
(static pressure)
Standard
Option
2.5
6
10
25
40
25
40
25
40
25
40
25
40
Steady:
Fluctuating:
Overpressure safety:
Overpressure safety, single,
dual or alternating sides
Standard
2.5
2.5
4
6
10
16
25
full scale value
0.9 x full scale value
40, 100, 250 or 400 bar
GB
Option
-
6
40
40
40
40
40
5