MAXIMUM AND MINIMUM TEMPERATURE
AND HUMIDITY
The maximum and minimum recorded indoor / outdoor
temperature and humidity will be automatically
stored in memory. To display these readings, press
[MEM] button to display the minimum reading and
press [MEM] button to display the maximum reading,
and then press [MEM] button to resume to the current
reading.
WEATHER FORECAST
The Main Unit is able to detect atmospheric pressure
changes. Based on the collected data, it can predict
the weather for the forthcoming 12 to 24 hours.
Symbol display
Forecast
Sunny
Partly
Cloudy
Cloudy
Color
Yellow
Green
Light Blue
Remark:
1. The accuracy of a general pressure-based weather
forecast is at about 70%.
2. The weather forecast may not necessarily reflect the
current situation
3. The Sunny icon, as applies to night time, implies
clear weather
There is a trend indicator on the display to show the
measured atmospheric pressure are rising
steady
, or Falling
.
63
TRANSMISSION COLLISION
Signals from other household devices, such as door
bells, home security systems and entry controls, may
interfere with those of this product and cause
temporarily reception failure. This is normal and does
not affect the general performance of the product. The
transmission and reception of temperature readings
will resume once the interference recedes.
HOW TO SET THE RADIO CONTROLLED CLOCK
1. After the batteries are installed. The clock will
automatically search the radio signal. It takes about
3-5 minutes to finish this process.
2. If user wishs to disable the auto-reception feature,
hold the [ + ] button for 2 seconds to disable it.
3. To enable the auto-reception feature again, holds the
[ + ] for 2 seconds again to force it receive and allow
it receive at desired time.
4. If the radio signal is received, the date & time will be set
automatically with radio control signal icon [ ] turns on.
5. If the clock fails to receive the time signal, it will be show
as [
] icon. Then user can set the time manually.
HOW TO SET THE CLOCK MANUALLY
To set the clock manually, hold [MODE] for two
seconds it will show the display language. Use [ + ] or
[ – ] to change it. Press [MODE] to confirm. Repeat
the same procedure to set year, month, date, 12/24 hour
format, hour and minute. During the setting, use [ + ]
or [ – ] will increase or decrease the value rapidly.
For display language, you are able to select English (En),
German (DE), French (Fr), Italian (IT), Spanish (SP)
and Dutch (DU).
If there is an item you do not need to change, simply
press [MODE] to bypass the item.
When you finished the change, press [MODE] to exit.
The display will return to the clock mode.
65
COMFORT LEVEL INDICATORS
The comfort level indicators COM, WET or DRY will
tell you if the current environment is comfortable, too
wet, or too dry. The comfort indicators will appear on
the display of the Main Unit when the following
conditions are satisfied:
Indicator
displays
on the unit
Rainy
Snowy
Indicator
Purple
White
DISCONNECTED SIGNALS
If without obvious reasons the display of the outdoor
temperature goes blank, hold [SEARCH] button for 2
seconds to enforce an immediate search. If that fails, check:
1. The Remote Sensor Unit is still in place
2. The batteries of both the Remote unit and the Main
3. The transmission is within range and path is clear of
,
HOW TO SET THE ZONE TIME
1. To set the zone time,
2. Press [MODE] until at zone time display mode
3. Hold [MODE] for two seconds, the zone time
4. Enter the offset using [ + ] or [ – ].
5. Press [MODE] to exit.
HOW TO SET THE ALARM
There are total two alarms, namely alarm 1 and
alarm 2 which can be operated by press [AL. 1] an
[AL. 2] respectively. The alarm setting procedure is
listed as below.
SETTING ALARM 1
1. Press [AL. 1]
2. Press [ + ] or [ – ] to turn on / off the alarm function.
3. Press and Hold [AL. 1] button until the hour for
4. Set the hour by press [ + ] or [ – ], and then press
5. Then, to set the minute by press [ + ] or [ – ], and
6. If you would like to leave the alarm display and
Temperature
Humidity
Range
Range
40%RH
20˚C to 25˚C
to
COM
70%RH
OVER
-5˚C to +50˚C
WET
70%RH
Below
-5˚C to +50˚C
DRY
40%RH
Less than 20˚C
40%RH
No
or More than
to
25˚C
70%RH
Unit. (Notes: when the temperature falls below freezing
point, the batteries of outdoor units will freeze,
lowering their voltage supply and the effective range.
obstacles and interference. Shorten the distance
when necessary.
64
which there is a 'ZONE' icon on LCD display,
offset will be displayed.
alarm is flashing
[AL. 1] button to confirm.
then press [AL.1] button to confirm.
show calendar, press [MODE] to show calendar. If
you would like to switch to alarm 1 display, press
[AL.1] button.
66
Shows that the
Current
Environment
Comfortable
Too wet
(moisture)
Too Dry
No comment