TROUBLESHOOTING

Check the following before contacting technical support:
Problem
The unit does not
work.
The device does not
dehumidify.
The dehumidifier
works, but reduces the
relative humidity insuf-
ficiently.
Warn signal filter
exchange / light ring
around the user
interface blinking blue
FAILURE OF HUMIDITY AND/OR TEMPERATURE SENSOR
1
When the electrical wire of humidity/temperature sensor breaks, the symbol
flash and "0°C - 0%RH" is showed in the LCD display. The dehumidifier will
automatically turn into continuous dehumidifying mode and will not longer be
working according to the required set humidity. The actual dehumidification
performance will not be influenced.
2
When the temperature sensor of the evaporator behind the filter is short circuiting,
the symbol of defrost
dehumidifying and defrosting mode: dehumidifying for 20 minutes, then defrosting
for 5 minutes. In this case the dehumidifier will continue to work with lower
efficiency.

CONDITIONS OF WARRANTY

There is a two-year warranty on your dehumidifier from the date of purchase. All material
or manufacturing defects will be repaired free of charge.
Cause
The powercord is not con-
nected.
The required humidity setting
is too high.
The water container is full.
The water container has not
been replaced correctly.
The air filter is clogged.
The temperature or relative
humidity in the room where
the device is operating is too
low.
The room is too large.
There are too many sources of
humidity.
There is too much ventilation.
Dirty filter
will wink, and the appliance turns into factory pre-set
Solution
Insert the plug into the wall
outlet.
Turn the required humidity to
a lower desired setting.
Remove the water from the
container.
Place the water container in
the correct position.
Clean the air filter.
It is normal that the device
does not dehumidify in these
conditions.
We recommend using a
dehumidifier with a greater
capacity.
We recommend using a
dehumidifier with a greater
capacity.
Reduce ventilation (e.g. close
curtains and shut doors).
"Replace the filter package
and
reset the filter alarm"
4