Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
and required (set) humidity are memorised until power supply is restored.
PROTECTION AGAINST EXTREME HIGH OR LOW TEMPERATURE
1
When sensor on the air intake detects ambient temperature ≤ 0°C or ≥ 40 °C, the
dehumidifier will shut off automatically for protection reasons and produces a
continuous acoustical alarm signal with 3 long and 2 short signals.
When sensor detects ambient temperature ≤0 °C: "0°C" is shown in the LCD display.
When sensor detects ambient temperature ≥40 °C: "40°C" is shown in the LCD display.
2
When sensor on the evaporator detects its temperature ≥40 °C, the dehumidifier will
shut off automatically (protection), and the symbol of automatic defrost
illuminates.
In this protection mode:
Control buttons do not longer function. Remove the power cord plug from mains
and reposition it again to restart the unit.
After the protection mode of extremely low & high temperature, the appliance will
not keep its memory function when restart.

AIR FILTER

The dehumidifiers are equipped with a 3-layer filter package to clean the circulated room
air. The 3-layer filter package consists of a screen filter and (separately packed) 3M™ HAF
and active carbon filter. These filters must be placed according to the instructions before
operating the dehumidifiers.
Picture 7
1
Screen filter; to remove bigger dust particles.
2
3M™ HAF filter; to remove unhealthy particles from the air such as pollen, bacteria,
animal dander and dust.
3
Active carbon filter sheet; to remove odours.
4
89

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

D 512D 516D 520

Inhaltsverzeichnis