Herunterladen Inhalt Inhalt Diese Seite drucken

Systemexklusives Datenformat - Waldorf X-Pole Dual Filter Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Systemexklusives Datenformat

Waldorf Xpole Sys-Ex
============================================================================================
1. General
============================================================================================
The Xpole uses two forms of Sys-Ex messages:
I)
Non-realtime Sys-Ex
II) Xpole Sys-Ex
Both message types are either
a) requests
b) indications
Combining these two yields the Xpole has 4 different Sys-Ex message groups:
I)
Non-realtime Sys-Ex request
II)
Sys-Ex non-realtime indication
III) Xpole Sys-Ex request
IV)
Xpole Sys-Ex indication
Notations in this document:
XXh : hexadecimal (e.g. 7Fh means hexadecimal 7F)
============================================================================================
2. Non-realtime Sys-Ex
============================================================================================
Non-realtime Sys-Ex messages are described in the MIDI standard, in the Xpole two
messages are used:
request device ID = F0h 7Eh DEVID 06h 01h F7h
|
|
|
|
|
|
+------------------------ begin of Sysex
sending this message to the Xpole will cause the transmission
of the device ID indication message....
device ID indication
= F0h 7Eh DEVID 06h 02h 3Eh 0Fh 00h 00h 00h VS_H VS_L 00h 00h F7h
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+----------------------------------------------------- DEVID = 0..7E: (MIDI Ch - 1)
|
|
|
+---------------------------------------------------------- non-realtime sysex
+-------------------------------------------------------------- begin of Sysex
this message is sent after a device ID request..
============================================================================================
2. Xpole Sys-Ex
============================================================================================
Xpole sysex messages have the following syntax:
F0 MAN MOD DEV TYP .... data .... F7
where
MAN = manufacturer code -> 3E (Waldorf)
MOD = model -> 0F (Xpole)
DEV = Device ID (MIDI Channel - 1)
TYP = type of message
... data ... = data related to the message
Bedienhandbuch X-Pole
|
|
|
|
+-- end of Sysex
|
|
|
+------ message = request device ID
|
|
+---------- general info
|
+--------------- DEVID = 0..7E: device ID (MIDI Ch - 1)
|
+-------------------- non-realtime sysex
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
+---+---+---+------------------------ family member (0F=Xpole)
|
|
+---------------------------------------- Manufacturer (3E=Waldorf)
|
+-------------------------------------------- message = ID indication
+------------------------------------------------ general info
7F
: broadcast
|
|
|
|
|
+-- end of Sysex
|
+----+---+---+------ software version (H.L)
7F
: broadcast
45

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis