Introduction

This booklet contains instructions for the use and maintenance of the DIVER and DIVER HF series water pumps, both single phase and
three phase. The DIVER and DIVER HF electropump has been designed to pump clean water not containing abrasive particles it can be
used in wells with a minimum diameter of 125 mm (5"), as well as in containers or cisterns. The use of the pump for irrigation,
gardening, and in the residential and household field is subject to local legislation. Before installing and using the pump, read the
following instructions carefully.
Read this manual carefully bifore installing and using the product.
The manufacturer declines any responsibility in case of accidents or damages caused by improper use of the water pump or due to
negligence or lack of observance of the instructions described in this booklet or use of the pump under conditions that differ from the
ratings on the nameplate.
2
Description of Diver water pump
The electopump DIVER and DIVER HF is supplied in a solid carton box, with its instruction booklet, ready for installation, complete with
electric cable.
These are Diver data :
Power
Model
W
Max. Amp.
75M
850
100M
1100
150M
1600
200M
2300
100M HF 1100
150M HF 1690
200M HF 2140
Power I max. Fatt. Pot. Capacity L/min Head m.c.a.
Model
W
Amp.
75T
800
100T
1190
150T
1590
200T
2150
100T HF 1200
150T HF 1800
200T HF 2100
3

Stocking and handling

The pump should be stocked in vertical position, in a clean and dry place and inside its original packing. When storing do not put
weights or other boxes on top.
Never lift or transport the pump by its electric cable.
CAUTION
4

Preliminary inspection

Unpack the pump and check its integrity in all its components.
Check that the data on the nameplate are according to your needs. In particular the electrical data (voltage, phase number,
frequency, rated power and amps) have to correspond with those of the power supply where you want to connect the pump.
Check, in the case of a preinstalled control box and of a single phase pump that the value of the capacitor is according to the one
stamped on the nameplate.
In case of anomalies or any doubt please immediately contact your supplier or service point signaling the facts.
Never use the pump in case of doubts about its safety or its use.
CAUTION
5
Conditions of use
The following conditions must be observed when using the water pump:
Temperature of pumping liquid between : Min. +0°C – Max. +35°C
Max. depth : 70 mt
Voltage variation allowed : +/- 5%
Starti for hour : Max. 40
Minimum positive head level : 150mm
1 phase pumps Diver
I
Capacitor Fatt. Pot. Capacity L/min Head m.c.a.
mF
Cos.Fi
4,6
16
0,89
5,9
20
0,89
7,8
30
0,89
10
35
0,89
6,2
20
0,89
8,1
30
0,89
10
35
0,97
3 phase pumps Diver
Cos.Fi
min
max
1,7
0,78
10
80
2,4
0,78
10
80
3,3
0,80
10
80
4,9
0,80
10
80
2,5
0,80
25
200
3,5
0,79
25
200
4,9
0,82
25
200
min
max
min max
5
80
5
36
5
80
10
48
5
80
13
72
5
80
16
96
25
200
10
28
25
200
10
42
25
200
10
56
min max
5
36
10
48
13
72
16
96
10
28
12
42
16
56
6