Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F,
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total
power on the rating plate. You can also
refer to the table:
Total power (W)
maximum 10380
Connecting the terminal board
The appliance has a six-pole terminal
board. The jumpers (bridges) are set for
operation on a 400 V three-phase with a
neutral wire.
1
2

ENERGY EFFICIENCY

Product Fiche and information according to EU 65-66/2014
Supplier's name
Model identification
Energy Efficiency Index
Energy efficiency class
Section of the ca-
ble (mm²)
3 phases: 5 x 2.5
2 phases: 4 x 4.0
1 phase: 3 x 6.0
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
3
4
5
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different, rearrange
the jumpers on the terminal board (refer to
the connection diagram below). Connect
the ground cable to the terminal. After you
connect the supply cable to the terminal
board, attach it with a junction clamp.
1 2 3 4 5
230V 3~
L1
1 2 3 4 5
230V 1~
L1
1 2 3 4 5
400V 2N~
L1
1 2 3 4 5
400V 3N~
L1 L2 L3
Juno
JH060A5
103.8
A
L2
L3
PE
N
PE
L2
N
PE
N
PE