Motor run time

The Vestamatic VestaFunk MS12 – 500 / MS14 – 500 allows you to adapt
the switching time of the output to the actual motor run time of your
drives. This can be carried out by means of DIP switches 5 – 8.
Switches
5
6
7
8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
20:23
Seite 39
Settings
Motor run time
180 seconds
3 seconds
10 seconds
15 seconds
18 seconds
21 seconds
24 seconds
27 seconds
30 seconds
35 seconds
40 seconds
50 seconds
60 seconds
80 seconds
100 seconds
120 seconds
- 39 -
G

Technical data and dimension diagrams

Technical data
Power supply:
230 VW, 50 Hz
Rated power:
1.5 W
Output:
Maximum load:
4 A, 230 VW, cos f > 0.8
Switching time:
3 – 180 seconds
Operating temperature:
0 °C (32 °F) to +40 °C (104 °F)
IP class:
IP40
Transmitter frequency:
433,92 MHz
Transmitter battery:
12 V, Typ 23A, 23L, EL12, VR22, MN21
The radio transmitter comprises a battery containing toxic substances.
The consumer is obliged to correctly recycle the battery
(Guideline 91/157/EWG).
All technical data is subject to change!