Technical Data Technical Data - janitza UMG 96 RM-CBM Installationsanleitung

Vorschau ausblenden Andere Handbücher für UMG 96 RM-CBM:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Establish connection to PC
Establish connection to PC
11
11
Programming the voltage transformer
14
Programming the voltage transformer
14
The 3 most common connections for
The 3 most common connections for
communication between PC and device are
communication between PC and device are
1. Switch to programming mode.
1. Switch to programming mode.
mary
described in the following:
described in the following:
2. The symbols for programming mode PRG,
2. The symbols for programming mode PRG,
and for the current transformer CT appear.
and for the current transformer CT appear.
1.
1.
USB (Typ A)
USB (Typ B)
USB (Typ A)
PC
3. Use button 2 to change to programming
3. Use button 2 to change to programming
PC
mode for the voltage transformer.
mode for the voltage transformer.
PC and UMG 96 RM-P/-CBM require a fixed IP address.
PC and UMG 96 RM-P/-CBM require a fixed IP address.
ndary
4. The symbols for Programming mode PRG,
4. The symbols for Programming mode PRG,
and for the voltage transformer VT appear.
and for the voltage transformer VT appear.
bol
5. Press button 1 - the first digit of the input
5. Press button 1 - the first digit of the input
2.
2.
RS232
RS232
RS232
RS232
PC
PC
field for the primary voltage flashes.
field for the primary voltage flashes.
RS485
6. Use button 2 to select the value of the
6. Use button 2 to select the value of the
Connection of the UMG 96 RM-P/-CBM
Connection of the UMG 96 RM-P/-CBM
1st digit.
1st digit.
via interface converter.
via interface converter.
7. Use button 1 to change to the 2nd digit.
7. Use button 1 to change to the 2nd digit.
8. Use button 2 to select the value of the
8. Use button 2 to select the value of the
2nd digit.
2nd digit.
3.
3.
Ethernet
Ethernet
9. Use button 1 to change to the 3rd digit.
UMG 604
PC
9. Use button 1 to change to the 3rd digit.
PC
UMG 604
10. Use button 2 to select the value of the
10. Use button 2 to select the value of the
Connection of the UMG 96 RM-P/-CBM
3rd digit.
Connection of the UMG 96 RM-P/-CBM
3rd digit.
via an UMG 604 as gateway.
via an UMG 604 as gateway.
11. Confirm with button 1.
11. Confirm with button 1.
12. The complete number flashes.
12. The complete number flashes.
More details on device configuration and
13. Use button 2 to select the decimal place and
More details on device configuration and
13. Use button 2 to select the decimal place and
communication can be found from section 13.
thus the unit of the primary voltage.
communication can be found from section 13.
thus the unit of the primary voltage.
14. Confirm with button 1.
14. Confirm with button 1.
C
C
15. The input range of the secondary voltage
NOTE "Profibus interface"!
15. The input range of the secondary voltage
NOTE "Profibus interface"!
flashes.
Information for integrating your UMG 96
flashes.
Information for integrating your UMG 96
16. Set the secondary voltage with button 2.
RM-P in your Profibus network can be
16. Set the secondary voltage with button 2.
RM-P in your Profibus network can be
found in the user manual.
found in the user manual.
(gedrehtes Patchkabel)
(gedrehtes Patchkabel)
(gedrehtes Patchkabel)
(gedrehtes Patchkabel)
Technical data
16
Technical data
16
General information
General information
Net weight
Net weight
approx. 358 g
(with attached connectors)
(with attached connectors)
Packaging weight
Packaging weight
approx. 790 g
(including accessories)
(including accessories)
Lithium battery CR2032, 3 V
Battery
Battery
(approval i.a.w. UL 1642)
40000 h
(after this period of time
Service life of
Service life of
the background lighting
background lighting
background lighting
efficiency will reduce by
approx. 50%)
ns-
Transport and storage
Transport and storage
-
The following information applies to devices which are trans-
The following information applies to devices which are trans-
ported or stored in the original packaging.
ported or stored in the original packaging.
Free fall
Free fall
1 m
Temperature
K55 (-25° C to +70° C)
Temperature
Relative humidity
0 to 90% RH
Relative humidity
ns-
Ambient coditions during operation
Ambient coditions during operation
The UMG 96RM is intended for weather-protected, stationary
The UMG 96RM is intended for weather-protected, stationary
use. Protection class II i.a.w. IEC 60536 (VDE 0106, Part 1).
use. Protection class II i.a.w. IEC 60536 (VDE 0106, Part 1).
Operating temperature range
K55 (-10° C .. +55° C)
Operating temperature range
Relative humidity
0 to 75% RH
Relative humidity
Operating altitude
0 .. 2000 m above sea level
Operating altitude
Degree of pollution
2
Degree of pollution
n
Mounting position
vertical
Mounting position
n.
Forced ventilation is not
Ventilation
Ventilation
required.
Protection against ingress of
Protection against ingress of
solid foreign bodies and water
solid foreign bodies and water
- Front side
IP40 i.a.w. EN60529
- Front side
- Rear side
IP20 i.a.w. EN60529
- Rear side
- Front with seal
IP54 i.a.w. EN60529
- Front with seal
Fig. Rear side view of UMG 96 RM-P
Fig. Rear side view of UMG 96 RM-P
17. Confirm with button 1.
17. Confirm with button 1.
18. Exit programming mode by simultaneously
18. Exit programming mode by simultaneously
pressing buttons 1 and 2 (1 sec.). Use
pressing buttons 1 and 2 (1 sec.). Use
USB (Typ B)
UMG
UMG
button 2 to change to the programming
button 2 to change to the programming
96 RM-P/-CBM
96 RM-P/-CBM
mode for the parameter list.
mode for the parameter list.
RS485
RS485
UMG
UMG
96 RM-P/-CBM
RS485
96 RM-P/-CBM
UMG
UMG
RS485
RS485
96 RM-P/-CBM
96 RM-P/-CBM
RS485
UMG
RS485
UMG
96 RM-P/-CBM
96 RM-P/-CBM
Recommendation for the Ethernet connection:
Recommendation for the Ethernet connection:
Fig. "Voltage transformer" input field
Fig. "Voltage transformer" input field
Use at least a CAT5 cable!
Use at least a CAT5 cable!
UMG
UMG
RS485
RS485
96 RM-P/-CBM
96 RM-P/-CBM
C
C
NOTE!
NOTE!
m
m
• Changes are only applied after exiting
Property damage due to
• Changes are only applied after exiting
programming mode.
incorrect network settings
programming mode.
CAUTION!
CAUTION!
• For further information on voltage
• For further information on voltage
Incorrect network settings can cause faults in
Incorrect network settings can cause faults in
transformers and voltage transformer
transformers and voltage transformer
the IT network!
the IT network!
ratios, see the user manual.
ratios, see the user manual.
Find out the correct Ethernet network
Find out the correct Ethernet network
settings for your device from your network
settings for your device from your network
administrator.
administrator.
Supply voltage
Supply voltage
Option 230 V:
approx. 358 g
AC 90 V - 277 V (50/60 Hz) or
DC 90 V - 250 V, 300 V CATIII
approx. 790 g
Nominal range
Nominal range
Option 24 V:
Lithium battery CR2032, 3 V
AC 24 V - 90 V (50/60 Hz) or
(approval i.a.w. UL 1642)
DC 24 V - 90 V, 150 V CATIII
40000 h
Operating range
Operating range
+-10% of the nominal range
(after this period of time
the background lighting
UMG 96 RM-P
Option 230 V: max. 7,5 VA / 4 W
UMG 96 RM-P
efficiency will reduce by
Option 24 V: max. 6,5 VA / 5 W
Power consumption
Power consumption
approx. 50%)
UMG 96 RM-CBM
UMG 96 RM-CBM
Option 230 V: max. 6 VA / 3 W
Power consumption
Option 24 V: max. 5 VA / 3 W
Power consumption
Internal fuse,
Internal fuse,
Type T1A / 250 VDC / 277 VAC
not replaceable
according to IEC 60127
not replaceable
Option 230 V: 6-16 A
1 m
Recommended over-
Recommended over-
Option 24 V: 1-6 A
K55 (-25° C to +70° C)
current protection device
current protection device
(Char. B)
for the line protection
for the line protection
0 to 90% RH
(IEC/UL approval)
Voltage measurement
Voltage measurement
3-phase, 4-conductor
3-phase, 4-conductor
systems with rated
277 V/480 V (+-10%)
systems with rated
K55 (-10° C .. +55° C)
voltages up to
voltages up to
0 to 75% RH
3-phase, 3-conductor
3-phase, 3-conductor
0 .. 2000 m above sea level
systems, unearthed, with
systems, unearthed, with
IT 480 V (+-10%)
2
rated voltages up to
rated voltages up to
vertical
Overvoltage category
300 V CAT III
Overvoltage category
Forced ventilation is not
Measurement voltage surge 4 kV
Measurement voltage surge 4 kV
required.
Protection of
Protection of
1 - 10 A
voltage measurement
(With IEC / UL approval)
voltage measurement
IP40 i.a.w. EN60529
0
to 300 Vrms
1)
IP20 i.a.w. EN60529
Measurement range L-N
Measurement range L-N
(max. overvoltage 520 Vrms )
IP54 i.a.w. EN60529
Controls and button functions
12
12
Programming parameters
15
15
The device is operated with buttons 1 and 2,
whereby the following distinctions are made:
1. Switch to programming mode.
• Short press (button 1 or 2):
2. The symbols for programming mode PRG,
Next step (+1).
• Longer press (button 1 or 2):
3. Press button 2 twice to change to the
Previous step (-1).
4. The input area of the parameter list appears.
The device differentiates between display and
Voltage transformer,
5. Confirm with button 1 - the first digit of the
Voltage transformer,
programming mode.
primary
primary
Programming mode
Programming mode
C
Display mode
Unit indicator
Unit indicator
• Buttons 1 and 2 can be used to scroll
Voltage transformer,
Voltage transformer,
between the measured value indications.
secondary
secondary
• The measured value indication shows up to
Voltage transformer
Voltage transformer
3 measured values.
symbol
symbol
• A time for the automatic display change
between the measured value indications can
be configured in the GridVis® software.
Programming mode
6. Use button 2 to select the value of the
Property damage due to
• Hold buttons 1 and 2 depressed
incorrect network settings
simultaneously for 1 second to change
7. Continue the process for the next digits of
between display mode and programming
mode. The text PRG appears in the display.
• Configure the necessary settings for the
8. Exit programming mode by simultaneously
operation of the device in programming
mode.
Voltage measurement
Option 230 V:
Measurement range L-L
AC 90 V - 277 V (50/60 Hz) or
DC 90 V - 250 V, 300 V CATIII
Resolution
Option 24 V:
Crest factor
AC 24 V - 90 V (50/60 Hz) or
Impedance
DC 24 V - 90 V, 150 V CATIII
Power consumption
+-10% of the nominal range
Option 230 V: max. 7,5 VA / 4 W
Sampling rate
Option 24 V: max. 6,5 VA / 5 W
Frequency range of the
Option 230 V: max. 6 VA / 3 W
fundamental oscillation -
Option 24 V: max. 5 VA / 3 W
resolution
Type T1A / 250 VDC / 277 VAC
1) ... The device determines measured values only if the Voltage
according to IEC 60127
Option 230 V: 6-16 A
Option 24 V: 1-6 A
(Char. B)
(IEC/UL approval)
Current measurement I1 - I4
Rated current
Measurement range
Crest factor
277 V/480 V (+-10%)
Resolution
Overvoltage category
IT 480 V (+-10%)
Measurement voltage
surge
300 V CAT III
Power consumption
Overload for 1 sec.
1 - 10 A
Sampling rate
(With IEC / UL approval)
0
to 300 Vrms
1)
(max. overvoltage 520 Vrms )
11 / 12
11 / 12
Controls and button functions
Fig. Display UMG 96 RM-P/ -CBM
Programming parameters
The device is operated with buttons 1 and 2,
whereby the following distinctions are made:
1. Switch to programming mode.
• Short press (button 1 or 2):
2. The symbols for programming mode PRG,
Next step (+1).
and for the current transformer CT appear.
and for the current transformer CT appear.
• Longer press (button 1 or 2):
3. Press button 2 twice to change to the
Previous step (-1).
programming mode for the parameter list.
programming mode for the parameter list.
4. The input area of the parameter list appears.
The device differentiates between display and
5. Confirm with button 1 - the first digit of the
programming mode.
parameter address flashes.
parameter address flashes.
C
NOTE!
NOTE!
Display mode
• A detailed parameter list with setting
• Buttons 1 and 2 can be used to scroll
• A detailed parameter list with setting
areas and pre-settings can be found
areas and pre-settings can be found
between the measured value indications.
in the user manual or the Modbus
• The measured value indication shows up to
in the user manual or the Modbus
address list on our website.
address list on our website.
3 measured values.
Delivery
• The parameter addresses of the
• A time for the automatic display change
• The parameter addresses of the
device address (000) and the Baud
between the measured value indications can
device address (000) and the Baud
• The programming mode can be protected with
rate (001) are explained in the
rate (001) are explained in the
be configured in the GridVis® software.
following.
• Button 2 switches between the programming
following.
Programming mode
6. Use button 2 to select the value of the
• Hold buttons 1 and 2 depressed
1st digit.
1st digit.
simultaneously for 1 second to change
7. Continue the process for the next digits of
between display mode and programming
the parameter address and for the parameter
the parameter address and for the parameter
mode. The text PRG appears in the display.
settings.
settings.
• Configure the necessary settings for the
In order to switch from programming mode to display mode
8. Exit programming mode by simultaneously
• press buttons 1 and 2 simultaneously for 1 second.
operation of the device in programming
pressing button 1 and 2 (1 second). Use
pressing button 1 and 2 (1 second). Use
• do not press any buttons for 60 seconds (automatic).
mode.
button 2 to change back to the input field for
button 2 to change back to the input field for
the current transformer.
the current transformer.
Voltage measurement
0
to 520 Vrms
1)
0
1)
to 520 Vrms
Measurement range L-L
(max. overvoltage 900 Vrms )
(max. overvoltage 900 Vrms )
0.01 V
Resolution
0.01 V
2.45 (related to the measurement range)
Crest factor
2.45 (related to the measurement range)
4 MOhm / phase
Impedance
4 MOhm / phase
approx. 0.1 VA
Power consumption
approx. 0.1 VA
21.33 kHz (50 Hz), 25.6 kHz (60 Hz)
21.33 kHz (50 Hz), 25.6 kHz (60 Hz)
Sampling rate
for each measurement channel
for each measurement channel
Frequency range of the
45 Hz to 65 Hz
fundamental oscillation -
45 Hz to 65 Hz
0.01 Hz
resolution
0.01 Hz
1) ... The device determines measured values only if the Voltage
measurement input V1 voltage L1-N greater than 20 Vrms
measurement input V1 voltage L1-N greater than 20 Vrms
(4-wire measurement) or a voltage L1-L2 of larger 34 Vrms
(4-wire measurement) or a voltage L1-L2 of larger 34 Vrms
(3-wire measurement) is applied.
(3-wire measurement) is applied.
Current measurement I1 - I4
5 A
Rated current
5 A
0 to 6 Arms
Measurement range
0 to 6 Arms
1.98
Crest factor
1.98
0.1 mA (display 0.01 A)
Resolution
0.1 mA (display 0.01 A)
300 V CAT II
Overvoltage category
300 V CAT II
Measurement voltage
2 kV
2 kV
surge
approx. 0.2 VA (Ri = 5 mOhm)
Power consumption
approx. 0.2 VA (Ri = 5 mOhm)
120 A (sinusoidal)
Overload for 1 sec.
120 A (sinusoidal)
21.33 kHz (50 Hz), 25.6 kHz (60 Hz)
21.33 kHz (50 Hz), 25.6 kHz (60 Hz)
Sampling rate
for each measurement channel
for each measurement channel
L1
L1
L2
L2
L3
L3
Fig. Display UMG 96 RM-P/ -CBM
Max. value, HT/Consumption
Max. value, HT/Consumption
Min. value NT/Delivery
Min. value NT/Delivery
Mean value
Mean value
Parameter address
Parameter address
Programming
Programming
Programming mode
mode
Programming mode
mode
Summation measurement
Summation measurement
Phase conductor-
Phase conductor-
Parameter setting
Parameter setting
Phase conductor
Phase conductor
Password
Password
Fig. "Parameter list"
Fig. "Parameter list"
CT: Current transformer
CT: Current transformer
input field
VT: Voltage transformer
VT: Voltage transformer
input field
Set the device address (parameter address 000)
Set the device address (parameter address 000)
K1: Output 1
K1: Output 1
In a Master-Slave network via the RS485 interface
In a Master-Slave network via the RS485 interface
K2: Output 2
K2: Output 2
it is possible to distinguish between a master device
it is possible to distinguish between a master device
and other devices with the device address.
and other devices with the device address.
Button 2
Button 2
In the case of devices within this network, for the
Delivery
Button 1
In the case of devices within this network, for the
Button 1
parameter address 000 please note
parameter address 000 please note
• The programming mode can be protected with
• you must assign different device addresses.
• you must assign different device addresses.
a user password.
a user password.
• the parameter setting of the parameter address
• the parameter setting of the parameter address
• Button 2 switches between the programming
000 must lie within the range of 1 to 247
000 must lie within the range of 1 to 247
menus:
menus:
(0 and 248 to 255 are reserved).
(0 and 248 to 255 are reserved).
1. Current transformer
1. Current transformer
2. Voltage transformer
2. Voltage transformer
Set the Baud rate (parameter address 001)
Set the Baud rate (parameter address 001)
3. Parameter list
3. Parameter list
In a Master-Slave network via the RS485 interface,
In a Master-Slave network via the RS485 interface,
for each device:
for each device:
In order to switch from programming mode to display mode
• select a uniform Baud rate (parameter address
• select a uniform Baud rate (parameter address
• press buttons 1 and 2 simultaneously for 1 second.
001) (for settings see the user manual).
001) (for settings see the user manual).
• do not press any buttons for 60 seconds (automatic).
• select the number of stop bits
• select the number of stop bits
(parameter address 003) (0=1 Bit, 1=2 Bits).
(parameter address 003) (0=1 Bit, 1=2 Bits).
Data bits (8) and parity (none) are preset.
Data bits (8) and parity (none) are preset.
Digital outputs
Digital outputs
6 digital outputs, semiconductor relays, not short-circuit proof.
6 digital outputs, semiconductor relays, not short-circuit proof.
Switching voltage
max. 33 V AC, 60 V DC
Switching voltage
max. 33 V AC, 60 V DC
Switching current
max. 50 mAeff AC/DC
Switching current
max. 50 mAeff AC/DC
Response time
10/12 periods + 10 ms *
Response time
10/12 periods + 10 ms *
Pulse output (energy pulse)
Pulse output (energy pulse)
max. 50 Hz
max. 50 Hz
* Response time e.g. at 50 Hz: 200 ms + 10 ms = 210 ms
* Response time e.g. at 50 Hz: 200 ms + 10 ms = 210 ms
Digital inputs
Digital inputs
4 optional digital inputs, semiconductor relays,
4 optional digital inputs, semiconductor relays,
not short-circuit proof.
not short-circuit proof.
Maximum counter frequency
20 Hz
Maximum counter frequency
20 Hz
18V .. 28 V DC
18V .. 28 V DC
Input signal present
Input signal present
(typical 4 mA)
(typical 4 mA)
0 .. 5 V DC,
0 .. 5 V DC,
Input signal not present
Input signal not present
current less than 0.5 mA
current less than 0.5 mA
Cable length (digital inputs and outputs)
Cable length (digital inputs and outputs)
Up to 30 m
Unshielded
Up to 30 m
Unshielded
More than 30 m
Shielded
More than 30 m
Shielded
Serial interface
Serial interface
9.6 kbps, 19.2 kbps,
9.6 kbps, 19.2 kbps,
RS485 - Modbus RTU/Slave
RS485 - Modbus RTU/Slave
38.4 kbps, 57.6 kbps,
38.4 kbps, 57.6 kbps,
115.2 kbps
115.2 kbps
Stripping length
Stripping length
7 mm
7 mm
USB 2.0, type B, max.
USB 2.0, type B, max.
USB (receptacle)
USB (receptacle)
transfer rate 921.6 kbps
transfer rate 921.6 kbps
Profibus (only UMG96RM-P)
Profibus (only UMG96RM-P)
- Profibus DP/V0
- 9,6kbps to 12Mbps
- Profibus DP/V0
- 9,6kbps to 12Mbps
- Receptacle
- D-sub, 9-pole
- Receptacle
- D-sub, 9-pole

Werbung

loading

Diese Anleitung auch für:

Umg 96 rm-p