Herunterladen Diese Seite drucken

Cleaning, Maintenance, Storage And Ordering Spare Parts - Scheppach Hc06 Originalbetriebsanleitung

Vorschau anzeigen Andere Handbücher für HC06:
Verfügbare Sprachen

Verfügbare Sprachen

  • DEUTSCH, seite 1
When working with spray attachments and during tem-
porary use outdoors, the device must be connected to
a residual current circuit breaker with a trigger current
of 30 mA or less.
Damaged electrical connection cable.
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly.
Ensure that the connection cables are disconnected
from electrical power when checking for damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with designation H05VV-F.
The printing of the type designation on the connection
cable is mandatory.
AC motor
• The mains voltage must be 220 - 240 V~.
• Extension cables up to 25 m long must have a
cross-section of 1.5 square millimetres.
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Engine data - type plate
Connection type Y
If the mains connection cable of this device is dam-
aged, it must be replaced by the manufacturer, their
service department or a similarly qualified person to
avoid dangers.
11. Cleaning, maintenance, storage
and ordering spare parts
m Attention!
Pull out the mains plug before carrying out any clean-
ing and maintenance work! Risk of injury from electric
shock!
m Attention!
Wait until the equipment has cooled down completely!
Danger of burning!
m Attention!
Always depressurise the equipment before carrying out
any cleaning and maintenance work! Danger of injury!
11.1 Cleaning
• Keep the device as free of dust and dirt as possible.
Rub the device clean with a clean cloth or blow it off
with compressed air at low pressure.
• We recommend that you clean the device directly
after every use.
• Clean the device at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic
parts of the device. Make sure that no water can
penetrate the device interior.
• The hose and injection tools must be disconnect-
ed from the compressor before cleaning. The com-
pressor must not be cleaned with water, solvents or
similar. be cleaned.
11.2 Maintaining the pressure vessel (fig. 1)
m Attention! To ensure a long service life for the
pressure vessel (7), drain off the condensate after
each use by opening the drain screw (9).
Release the boiler pressure beforehand (see 11.4.1).
The drain screw is opened by turning it counterclock-
wise (when looking at the screw on the bottom of the
compressor) so that the condensate can be complete-
ly drained out of the pressure vessel. Then close the
drain screw again (turn clockwise). Check the pres-
sure vessel for rust and damage each time before use.
The compressor shall not be operated if the pressure
vessel is damaged or rusty.
If you discover damage, please contact the customer
service workshop.