2012/19/EU. In countries outside the European Un-
ion, different regulations may apply to the disposal of
waste electrical and electronic equipment.
14. Troubleshooting
Fault
The compressor does not
start.
The compressor starts but
there is no pressure.
Compressor running,
pressure shown on the
display, but tools are not
running.
26 | GB
Possible cause
Mains voltage not present.
Mains voltage too low.
Outdoor temperature too low.
Motor is overheated.
Non-return valve leaking.
The seals are damaged.
Hose connections leaking.
www.scheppach.com
Remedy
Check cable, mains plug, fuse and socket.
Avoid extension cables that are too long. Use
extension cables with sufficient conductor
cross-section.
Do not operate at outside temperatures below
+5°C.
Allow the motor to cool down.
If necessary, remedy the cause of the
overheating.
Replace the non-return valve.
Check the seals and have any damaged seals
replaced by a service centre.
Check compressed air hose and tools, replace
if necessary.