Attention! For short workpieces, use the push stick as
soon as you start cutting.
Cutting edges and strips, Fig. 26
Work process: Mount the longitudinal stop with a low
contact surface or use an auxiliary fence. Push the
workpiece forward with the push stick until the end of
the workpiece is in the area of the riving knife. Secure
long workpieces against tipping at the end of the cut-
ting process with a table extension.
Carrying out cross cuts, Fig. 27
Work process: Adjust the deflector strip such that
pieces cut off the workpiece cannot come into contact
with the rising part of the saw blade. Feed workpieces
only by means of transverse stop or transverse slide.
Do not remove waste pieces from the area of the
workpiece with your hands.
10. Maintenance
Warning! Pull out the mains plug before carrying out
any adjustments, maintenance or repair work!
General maintenance tasks
• Keep protective devices, air vents and the motor
housing as free of dust and dirt as possible. Rub
the device clean with a clean cloth or blow it off with
compressed air at low pressure.
• We recommend that you clean the device directly
after every use.
• Clean the device at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic
parts of the device. Make sure that no water can
penetrate the device interior.
• Oil the rotating parts once monthly to extend the life
of the tool. Do not oil the motor.
Service information
With this product, it is necessary to note that the follow-
ing parts are subject to natural or usage-related wear,
or that the following parts are required as consumables.
Wearing parts*: Saw blade, table inserts, push stick,
* may not be included in the scope of supply!
Spare parts and accessories can be obtained from
our service centre. To do this, scan the QR code on
the cover page.
11. Storage
Store the device and its accessories in a dark, dry and
frost-free place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Cover the electric tool to protect it from dust or moisture.
Store the operating manual with the electric tool.
12. Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the ap-
plicable VDE and DIN provisions. The customer's
mains connection as well as the extension cable used
must also comply with these regulations.
Important information
In the event of overloading, the motor will switch itself
off. After a cool-down period (time varies) the motor
can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the designation H07RN-F.
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
• The mains voltage must be 230 Volts / 50 Hz.
• Extension cables up to 25 m long must have a
cross section of 1.5 mm
have a cross section of 2.5 mm
• The mains connection is protected with a 16 A
slow-blow fuse.
Three-phase motor
• The mains voltage must be 400V, 50Hz.
• The mains connection and the extension cable
must have 5 conductors: 3 phase conductors + 1
neutral conductor + 1 earth conductor.
• The extension cable must have a minimum cable
cross-section of 1.5 mm
• The connection to the mains must be protected
with a 16 A slow-acting fuse.
www.scheppach.com
, and over 25 m long must
2
.
2
.
2
GB | 31