Configuratio
n
Switching time
The switching time can be set individually.
◆
If the switching time is set to 0, the
◆
selected output remains activated until the
other output is selected.
If the switching time is set to a value greater
◆
than 0, the output is only switched for the
duration of the switching time.
Example of continuous operation
Switching time is 0
◆
The output is switched by the green command
◆
on the control panel.
The output remains switched until the
◆
control panel switches to red.
Condition
You can configure whether the output should
◆
be restored when the decoder is started.
Connection
The last selected output connection is saved
◆
here.
Outputs
Example switching pulse
Switching time is 10
◆
The output is switched by the green command
◆
on the control panel.
The output is automatically
◆
switched off after 10 seconds.
Careful
For continuous operation of the outputs,
◆
ensure that the maximum load of the
outputs does not exceed 500mA.
The outputs are designed for up to 2A for
◆
short periods, but this does not apply to
the
Continuous operation.
Careful
The decoder only restores the last selected
◆
position if the switching time is set to 0.
12