Decoderwerk 20102 Benutzerhandbuch Seite 28

Verfügbare Sprachen

Verfügbare Sprachen

Configuratio
n
Switching time
The switching time can be set individually.
If the switching time is set to 0, the
selected output remains activated until the
other output is selected.
If the switching time is set to a value greater
than 0, the output is only switched for the
duration of the switching time.
Example of continuous operation
Switching time is 0
The output is switched by the green command
on the control panel.
The output remains switched until the
control panel switches to red.
Condition
You can configure whether the output should
be restored when the decoder is started.
Connection
The last selected output connection is saved
here.
Outputs
Example switching pulse
Switching time is 10
The output is switched by the green command
on the control panel.
The output is automatically
switched off after 10 seconds.
Careful
For continuous operation of the outputs,
ensure that the maximum load of the
outputs does not exceed 500mA.
The outputs are designed for up to 2A for
short periods, but this does not apply to
the
Continuous operation.
Careful
The decoder only restores the last selected
position if the switching time is set to 0.
12
loading