■ Do not piece or burn,even after use.
■ Be aware that refrigerants may not contain an odour.
■ Pipe-work shall be protected from physical damage and shall not be
installed in an unventilated space , if that space is smaller than 6 m2 .
■ Compliance with national gas regulations shall be observed.
■ Keep any required ventilation openings clear of obstruction.
■ The appliance shall be stored in a well-ventilated area where the room
size corresponds to the room area as specified for operation.
Any person who is involved with working on or
breaking into a refrigerant circuit should hold a current
valid certificate from an industry-accredited
WARNING
assessment authority, which authorizes their
competence to handle refrigerants safely in
accordance with an industry, recognized assessment
specification.
Servicing shall only be performed as recommended by
the equipment manufacturer. Maintenance and repair
requiring the assistance of other skilled personnel
WARNING
shall be carried out under the supervision of the
person competent in the use of flammable
refrigerants.
SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the following when
servicing an appliance with R32.
Checks to the area
Prior to beginning work on systems containing flammable refrigerants,
safety checks are necessary to ensure that the risk of ignition is minimized.
For repair to the refrigerating system, the following precautions shall be
complied with prior to conducting work on the system.
Work procedure
Work shall be undertaken under a controlled procedure so as to minimize
the risk of a flammable gas or vapor being present while the work is being
performed.
General work area
All maintenance staff and others working in the local area shall be
instructed on the nature of work being carried out. Work in confined spaces
- 9 -